Product Overview
- AC load bank from Rata (example model: R2000kW / 6 kV / 50 Hz) — a containerized, factory‑built resistive load bank designed and customizable to customer requirements.
- Rated power 2000 kW, rated voltage AC 6 kV, weight ≈ 6,500 kg.
- Built for on‑site generator testing and heavy industrial use with horizontal air intake and vertical air outlet (ducted).
Product Features
- Container type construction with protected air intake (cover and steel mesh).
- Dual control modes: local manual panel switching and remote computer automatic control with operation software (supports curves, charts, tables, data save and print).
- Power connection via bottom‑mounted tin‑plated copper bars and terminals.
- High‑quality resistive elements (8020 Ni‑Cr alloy finned resistors).
- Multiple protection and safety functions: high temperature, low air volume, short circuit, overcurrent, access control, smoke alarm and emergency stop.
- Cooling by axial fans; measured noise < 80 dB at 3 m.
- Marine C5 painting level for enhanced anti‑corrosion resistance.
- Designed for testing oilfield generator sets (but suitable for many other generator and power system tests).
Product Value
- Provides a reliable, repeatable load source to verify generator set performance, commissioning acceptance, and maintenance diagnostics.
- Enables automated test sequences and data logging/printing for traceability and reporting.
- Robust protections and corrosion resistance increase safety and longevity in harsh environments (e.g., oilfield, marine).
- Containerized, factory‑ready design simplifies transport, installation and on‑site commissioning, reducing downtime.
Product Advantages
- Manufactured under controlled production process with dedicated quality control — documented ISO and CE accreditations.
- Developed by an experienced supplier (Rata, established 2013) with multiple patents and software copyrights and a proven export record.
- Customizable solutions and strong after‑sales/service capability (on‑site acceptance testing, technical support).
- High power capacity (2 MW at 6 kV in the cited model) suitable for large generator sets, with industrial‑grade components and comprehensive safety features.
Application Scenarios
- Load testing and acceptance of oilfield and rental generator sets.
- Commissioning, routine maintenance and performance verification of standby and prime power generators.
- Power plant and substation testing, UPS and switchgear verification.
- Offshore and marine applications (C5 painting for corrosion protection).
- Factory test labs, industrial facilities, military and emergency power system validation.