Product Introduction
The SILV-1000L is a 1,000 kW resistive load bank developed for controlled testing of generator sets and other power equipment. At its rated voltage of 400 Vac, it enables operators to apply a substantial, measurable electrical load during commissioning, periodic maintenance, troubleshooting and performance checks. The voltage-dependent capacities listed for this model are 1,076 kW at 415 Vac, 902 kW at 380 Vac and 302 kW at 220 Vac; operation should follow the equipment manual and the confirmed site configuration.
Finned stainless-steel heating elements with nickel-chromium resistance cores provide the resistive load. Four 2.2 kW industrial fans drive horizontal airflow, and airflow switches monitor cooling conditions. Operators can use the local HMI and digital meter, or connect PC-based remote-control software through RJ45 Ethernet with Modbus TCP. Meter readings include voltage, current, power, frequency and power factor.
Designed for industrial deployment, the unit has a container-style enclosure, four castors, an approximate weight of 1,200 kg and a control chamber rated IP54. Fan-overload and low-airflow protection, thermal cut-out, control-circuit MCBs, local/remote interlocking and an emergency stop are incorporated. Before loading, provide the required auxiliary supply and unobstructed cooling airflow; confirm clearances, voltage, connection, load steps and operating duty with the supplier for each project.
Key Features and Advantages
Engineering Drawing (mm)
Product Specifications
| Electrical parameter | |
| Rated power | 1000kW |
| Power factor | 1.0 |
| Rated voltage. | 400Vac |
| Hz. | 50Hz. |
| Phase & wires | 3P4W |
| Load resolution | 1kW |
| Voltage Tolerance (Short Term Operation) | +5% |
| Load Element Tolerance | ± 3% |
| Load connection | Copper busbars |
| Control power | Auxiliary |
| Control voltage | 400Vac |
| Enclosure structure | |
| Canopy/ container | Container |
| Noise level | 85±3dB(A) |
| Body size(W*D*H mm) | 2225*1160*1710 |
| Air direction | Horizontal |
| Quantity of fans | 4* 2.2kW |
| Air volume(m³/kW/hour) | 70 |
| Portability | Castors*4 |
| IP grade of control chamber | 54 |
| IP grade of complete enclosure | 2X |
| Colour | Grey |
| Weight | 1200kgs approx. |
| Protections | |
| Fans overload protection | |
| Fans low air volume protection | |
| Thermal emergency cut-out | |
| Control circuit MCB | |
| Local/ Remote control mode inter-lock | |
| Emergency Stop | |
| Load bank control | |
| Temperature | -20 °C to +50°C |
| Latitude | ≤ 2000 m.a.s.l |
| Load switching | 3 Pole Contactor |
| Digital meter | V/A/kW/Hz/Pf. |
| Connection interface | RJ45 |
| Type of communication | Modbus TCP |
| Local control | HMI touch screen |
| Remote control | PC based software |
| Power derate at other voltages | |
| 415Vac | 1076kW (Overloading) |
| 400Vac | 1000kW |
| 380Vac | 902kW |
| 220Vac | 302kW |
Key details
FAQ
Deyang Rata Technology Co., Ltd.
Shenzhen Rata Technology Co., Ltd.