The Rata SILV-1000LT three-phase resistive load bank is a cost-effective professional load simulation device integrating 1000kW ultra-high power, 10kW coarse-grained control, industrial-grade heat dissipation, and multi-layer safety protection with vertical compact design. It is widely used for performance testing and verification of industrial power supplies, including large generators, UPS systems, and transformers.
Product Introduction
The Rata SILV-1000LT three-phase resistive load bank is a cost-effective professional load simulation device integrating 1000kW ultra-high power, 10kW coarse-grained control, industrial-grade heat dissipation and multi-layer safety protection with vertical compact design.
It is widely used for performance testing and verification of industrial power supplies including large generators, UPS systems and transformers.
Key Features and Advantages
Engineering drawingS (mm)
This info given is our standard load bank features. we are constantly looking to imporove our design.
We reserve the right to change with prior notice. The finished design maight slightly vary from this given TDS.
Key details
Main Parameters
| Model No. | SIL-V-1000L |
| Country of origin | China |
| Max capacity | 1000kW |
| Rated testing voltage | 400Vac |
| Frequency | 50Hz. |
| Phases | 3 |
| Wire(Star connection) | 4 |
| Load step resolution | 1 kW |
| Load step (kW) | 1+2+2+5+10+10+20+60+100+200*4 |
| Voltage Tolerance (Short Term Operation) | +5% |
| Load Element Tolerance | ± 6% |
| Insulation Test | 500Vac |
| Load Connections | Copper busbars |
| Protection | Thermal emergency cut out |
| Air-flow switch | |
| Fan overload protection | |
| Emergency stop | |
| ACH-Schneider EVS 2000A, # Isolator | |
| Control power | From internal main's load circuit |
| Cooling method | Air forced cooling |
| Airflow volume(Approx. CMM) | 50m3/kW/ h |
| Airflow direction | Horizonts |
| Load switching/contactor type | 3 pole AC contactors |
| Rated maximum ambient temp. operation | +60°C / +122°F |
| Rated minimum ambient temp. operation | -20°C/-4°F |
| Altitude rating | <2000m [m.a.s.l.] |
| Control chamber IP rating | IP 84 |
| Portability | 2 folkift holes |
| Enclosure dimentions | |
| Length(mm) | 2230 |
| Depth(mm) | 1430 |
| Height(mm) | 2068 |
| Weight(KG) | 1500 |
| Load bank control system | |
| Manual control | Push buttons |
| Remote control | Upper level PO based software |
| Communication | Modbus TCP |
| Test voltage(3 phases) | Power derating with lower voltage applied. |
| 400V | 1000 kW |
| 380V | 900 kW |
FAQ