loading
RATA SILV-1600L Standard Model 1600 kW / 400 Vac Resistive Load Bank for Generator Testing 1
RATA SILV-1600L Standard Model 1600 kW / 400 Vac Resistive Load Bank for Generator Testing 2
RATA SILV-1600L Standard Model 1600 kW / 400 Vac Resistive Load Bank for Generator Testing 3
RATA SILV-1600L Standard Model 1600 kW / 400 Vac Resistive Load Bank for Generator Testing 4
RATA SILV-1600L Standard Model 1600 kW / 400 Vac Resistive Load Bank for Generator Testing 5
RATA SILV-1600L Standard Model 1600 kW / 400 Vac Resistive Load Bank for Generator Testing 1
RATA SILV-1600L Standard Model 1600 kW / 400 Vac Resistive Load Bank for Generator Testing 2
RATA SILV-1600L Standard Model 1600 kW / 400 Vac Resistive Load Bank for Generator Testing 3
RATA SILV-1600L Standard Model 1600 kW / 400 Vac Resistive Load Bank for Generator Testing 4
RATA SILV-1600L Standard Model 1600 kW / 400 Vac Resistive Load Bank for Generator Testing 5

RATA SILV-1600L Standard Model 1600 kW / 400 Vac Resistive Load Bank for Generator Testing

The SILV-1600L is a RATA standard model 1,600 kW resistive load bank designed for commissioning, maintenance and performance verification of generators and other power systems.
5.0
Warranty time:
2 years
Delivery time:
8 weeks
ISO Certification:
ISO9001/ISO14001
Brand:
RATA
Factory Price:
Negotiate
Supply Ability:
200,000 Piece/Pieces per Month
Port:
Shanghai and Guangzhou are both available
Payment Terms:
L/C,Cash,Western Union,T/T, Paypal
Min.Order Quantity:
1 pcs
ODM & OEM:
Available
Certification:
CE 60204 Standard​
design customization

    oops...!

    no product data.

    Go to homepage
    SILV-1600L
    SILV-1600L

    Product Introduction

    It is rated at 400 Vac and features four industrial cooling fans that provide horizontal airflow, together with finned stainless-steel heating elements with nickel-chromium resistance cores. Operators can control the unit locally via the HMI or remotely using PC-based software over an RJ45 interface with Modbus TCP. Protection features include low-airflow, fan-overload and thermal protection, as well as an emergency stop. Its cabinet-style enclosure with lifting eyes and forklift pockets supports flexible deployment.

    IMG_0921 拷贝 (2)

    Product Features

    The SILV-1600L is a 1,600 kW resistive load bank developed for controlled testing of generator sets and other power equipment. At its rated voltage of 400 Vac, it enables operators to apply a substantial, measurable electrical load during commissioning, periodic maintenance, troubleshooting and performance checks. The voltage-dependent capacities listed for this model are 1,444 kW at 380 Vac and 484 kW at 220 Vac (3-phase); operation should follow the equipment manual and the confirmed site configuration.

    IMG_0924 拷贝 (2)

    Product Highlights

    Finned stainless-steel heating elements with nickel-chromium resistance cores provide the resistive load. Four 4.5 kW industrial fans (total fan power 18 kW) drive horizontal airflow, and airflow switches monitor cooling conditions. Operators can use the local HMI and digital meter, or connect PC-based remote-control software through RJ45 Ethernet with Modbus TCP. Meter readings include voltage, current, power, frequency and power factor. The load resolution is 1 kW — the PLC combines 16 switched stages up to 1,600 kW — and load switching is performed by 3-pole contactors.


    Designed for industrial deployment, the unit has a cabinet-style enclosure with an overall size of 2,800 × 1,726 × 2,060 mm (W × D × H), lifting eyes and forklift pockets, a weight of 2,500 kg, a noise level of 85±3 dB(A) and a control chamber rated IP54. Fan-overload and low-airflow protection, thermal cut-out, control-circuit MCBs, local/remote interlocking and an emergency stop are incorporated. Before loading, provide the required auxiliary supply and unobstructed cooling airflow; confirm clearances, voltage, connection, load steps and operating duty with the supplier for each project.

    undefined

    Key Features and Advantages

    IMG_6589 拷贝 2
    High-accuracy load testing
    1A load resolution and ±3% whole-machine accuracy.
    RATA SILV-1600L Standard Model 1600 kW / 400 Vac Resistive Load Bank for Generator Testing 10
    Voltage-specific capacity data
    Horizontal airflow design with 12 industrial fans (380 CFM per fan) for flexible installation.
    调节
    Industrial resistive elements
    Industrial-grade resistive elements with ±2.5% component tolerance compatibility for maximum utilization.
    company (5)
    Side-airflow design for flexible installation, with airflow monitoring
    HMI touch screen locally, PC software remotely via Modbus TCP (RJ45).
    RATA SILV-1600L Standard Model 1600 kW / 400 Vac Resistive Load Bank for Generator Testing 13
    Local and remote control
    Fans overload, thermal emergency cut-out and emergency stop.
    RATA SILV-1600L Standard Model 1600 kW / 400 Vac Resistive Load Bank for Generator Testing 14
    Layered protection
    Data center DC power, BESS, UPS, genset testing and power grid balancing.
    IMG_6594 拷贝
    Industrial-grade components
    IP23 enclosure, universal wheels and lifting lugs.
    IMG_6591 拷贝
    Practical deployment and maintenance
    Fast on-site installation with 200A DC quick connectors and a compact 600×1250×900mm footprint.

    Engineering Drawing (mm)

    1 (137)
    FRONT VIEW
    Touchscreen control • Cabinet height: 2060 mm
    2 (111)
    SIDE VIEW
    Depth: 1726 mm • Control-box lower edge: 610 mm
    3 (82)
    TOP VIEW
    Control cabinet: 702 mm wide × 276 mm projection
    4 (61)
    REAR VIEW
    Overall width: 2800 mm

    Product Specifications

    Electrical parameter
    Rated power 1600 kW
    Power factor 1
    Rated load voltage 400 Vac
    Frequency 50 Hz
    Phase & wires 3P4W + PE
    Load resolution 1 kW
    Voltage Tolerance (Short Term Operation) 5%
    Load Element Tolerance ± 3%
    Load connection Copper busbar
    Auxiliary power External auxiliary
    Auxiliary input voltage 400 Vac
    Enclosure structure
    Enclosure type Cabinet
    Noise level 85±3dB(A)
    Size (W × D × cabinet H, mm) 2800 × 1726 × 2060
    Weight 2500 kg
    Air direction Horizontal
    Quantity of fans 4 × 4.5 kW
    Air volume(m³/kW/hour) 70
    Portability Lifting eyes & forklift pockets
    IP grade of control chamber IP54
    IP grade of complete enclosure IP2X
    Protections
    Fans overload protection
    Fans low air volume protection
    Overtemperature cut-out: 120 °C
    Auxiliary circuit MCB
    Local/ Remote control mode inter-lock
    Emergency Stop
    Load bank control
    Temperature -20 °C to +50°C
    Altitude ≦2000 m.a.s.l
    Load switching 3 Pole contactor
    Digital meter V/A/kW/Hz/Pf.
    Interface RJ45
    Type of communication Modbus TCP
    Local control HMI touch screen
    Remote control PC based software
    Power derate at other voltages
    400 Vac 1600 kW
    380Vac 1444 kW
    220Vac(3 phase) 484 kW

    Key details

    IMG_0917 拷贝
    IMG_0917 拷贝
    IMG_0918 拷贝
    IMG_0918 拷贝
    IMG_0919 拷贝
    IMG_0919 拷贝
    IMG_0944 拷贝 (2)
    IMG_0944 拷贝 (2)
    IMG_0946 拷贝
    IMG_0946 拷贝
    IMG_0948 拷贝
    IMG_0948 拷贝
    IMG_0951 拷贝 (2)
    IMG_0951 拷贝 (2)
    IMG_0952 拷贝 (2)
    IMG_0952 拷贝 (2)

    FAQ

    1
    What testing applications is this load bank suitable for?
    Applications include genset testing, UPS testing, power-grid balancing, data-center server-load simulation and BESS testing. For generator sets, it can be used for resistive-load testing during commissioning, maintenance and performance checks.
    2
    How is the load bank controlled locally and remotely?
    Local operation is performed through the HMI touchscreen. Remote operation uses PC-based software and communicates via Modbus TCP over the RJ45 Ethernet interface. Before system integration, it is recommended to confirm the IP configuration, register map, communication permissions and software requirements.
    3
    What measurements can the meter display?
    The meter displays voltage, current, power, frequency and power factor (V/A/kW/Hz/Pf).
    4
    What conditions must be met before applying a load?
    First, connect the external auxiliary power supply and ensure that the cooling airflow is unobstructed. Then verify that the protection system is functioning properly before applying a load. During installation, prevent airflow obstruction and hot-air recirculation, and follow the equipment manual.
    5
    What environmental conditions and installation clearances should be considered?
    The ambient temperature range is −20°C to +50°C, and the maximum operating altitude is 2,000 m. If site conditions exceed these limits, consult the supplier regarding derating requirements. The unit uses horizontal airflow, so adequate clearance must be provided for air intake, hot-air discharge and maintenance. The specified noise level is 85±3 dB(A); select the installation location in accordance with site noise requirements.
    6
    What generator performance characteristics can this resistive load bank verify?
    It applies resistive real-power loads to the generator and supports checks of full-load capacity, steady-state operation and performance under changing load conditions. For dynamic load testing, confirm the available load steps, switching time and test profile with the supplier. As this model is specified as a resistive load bank, additional reactive-load capability may be required to evaluate reactive power, performance at a specified power factor or response to inductive loads.
    7
    How should cooling and hot-air discharge be evaluated during site deployment?
    The unit uses horizontal airflow and is equipped with four 4.5 kW fans (total fan power 18 kW). During testing, ensure that the air intake remains unobstructed and direct the hot exhaust away from the unit’s air intake and other equipment to prevent recirculation or heat-related impacts. Load testing generates a substantial amount of heat, so customers should assess indoor ventilation, exhaust direction, installation clearances and personnel separation in advance.
    8
    Do you provide installation and testing support?
    Yes, Rata provides on-site testing services, including equipment installation, configuration, and data logging.
    9
    Typical product delivery time?
    8 weeks.
    10
    Warranty service?
    2 years.
    11
    How many countries have you exported to?
    We export to over 80 countries worldwide.
    12
    Why choose us?
    We have ISO、CE certification and are Authorized factories for Siemens and Schneider Electric brands.
    13
    Spare parts service
    A spare parts list is supplied free of charge with each load bank, including intermediate relays, branch load fuses, air-pressure switches, Ni-Cr heating elements, indicators and push buttons.
    14
    Contact Information
    Contact: Mr. Gong Zhenhua | Email: gongzhenhua@rata.top | WhatsApp: +86 138 9027 0038 | Web: www.cnloadbank.com
    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products

    Deyang Rata Technology Co., Ltd.

    Contacts: Gong Zhenhua
    Phone/ WhatsApp: 0086-13890270038
    Address: Hongyu Road East, Jinshan Industrial Park, Luojiang Disctrict, Deyang. China

    Shenzhen Rata Technology Co., Ltd.

    Tel: 0086-15196362093
    Address: Room 102, Building 3, Huahan Science & Technology Industrial Park, No.16 West Jinniu Road, Heping Community, Pingshan Subdistrict, Pingshan District, Shenzhen, Guangdong Province, 518122, P.R.China
    Customer service