SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 1
SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 2
SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 3
SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 4
SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 5
SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 6
SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 7
SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 1
SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 2
SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 3
SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 4
SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 5
SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 6
SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 7

SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing

The SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank is designed for comprehensive testing and commissioning of diesel generators, UPS systems, power distribution equipment, and critical power infrastructure.
5.0
Warranty time:
2 years
Delivery time:
6 weeks
ISO Certification:
ISO9001/ISO14001
Brand:
RATA
Factory Price:
Negotiate
Supply Ability:
200,000 Piece/Pieces per Month
Port:
Shanghai and Guangzhou are both available
Payment Terms:
L/C,Cash,Western Union,T/T, Paypal
Min.Order Quantity:
1 pcs
ODM & OEM:
Available
Certification:
CE 60204 Standard​
design customization

    oops...!

    no product data.

    Go to homepage
    SIRL-250L TDS Technical documentation
    SIRL-250L TDS Technical documentation

    Product Introduction

    The SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank is designed for comprehensive testing and commissioning of diesel generators, UPS systems, power distribution equipment, and critical power infrastructure.


    By combining resistive and inductive loads in a single unit, it accurately simulates real operating conditions for factory acceptance testing (FAT), site commissioning (SAT), routine maintenance, and preventive testing. Featuring high-precision load control, an integrated generator testing system, Modbus TCP communication, and comprehensive safety protection, it provides a reliable, efficient, and intelligent solution for power system performance verification across industrial, commercial, and data center applications.

    0 (1) 拷贝

    Key Features and Advantages

    SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 9
    Combined Resistive and Inductive Load Simulation
    1 拷贝 (9)
    High-Precision Load Resolution
    1 (18)
    Intelligent Generator Testing System
    调节
    Flexible Local and Remote Control
    SIRL-250L 250kVA Intelligent Resistive & Inductive Load Bank For Generator Testing 13
    Comprehensive Safety Protection
    系统
    Compact Industrial Design
    冷却
    Industrial-Grade Cooling System

    ENCLOSURE DRAWINGS

    2 (99)
    2 (99)
    1 (123)
    1 (123)

    Main Parameters

    Technical Data Sheet(250kVA RL load bank)
    Apparent power 250 kVA
    Active Power 200.5kW
    Resistive Active Steps (0.5 + 1 + 2 + 2 + 5 + 10 + 10 + 20 + 50 + 100 )kW
    Inductive Reactive Power 150.5kvar
    Inductive Reactive Steps (0.5 + 1 + 2 + 2 + 5 + 10 + 10 + 20 + 50 + 50) kVar
    Power factor 0.8
    Rated voltage. 400Vac
    Hz. 50Hz.
    Phase & wires 3P4W+PE
    Active power load resolution 0.5kW
    Inductive power load resolution 0.5kVar
    Voltage Tolerance(Short Term Operation) +5%
    Load Element Tolerance ± 3%
    Load connection Copper busbars
    Control power Auxiliry
    Control voltage 400Vac 50Hz.
    Load bank control
    Temperature -20 °C to +50°C
    Latitude ≦2000 m.a.s.l
    Load swithing 3 Pole contactor
    Digital meter V/A/kW/kVar/kVA/Hz/PF
    Interface RJ45
    Type of communication Modbus TCP
    Load control Push Buttons
    Remote control PC based software

    Key details

    IMG_4078_副本 拷贝
    IMG_4078_副本 拷贝
    IMG_4084_副本 拷贝
    IMG_4084_副本 拷贝
    IMG_4089_副本 拷贝
    IMG_4089_副本 拷贝
    IMG_4086_副本 拷贝
    IMG_4086_副本 拷贝
    IMG_4129 拷贝
    IMG_4129 拷贝
    IMG_4136_副本 拷贝
    IMG_4136_副本 拷贝
    IMG_4139_副本 拷贝
    IMG_4139_副本 拷贝
    IMG_4205 拷贝
    IMG_4205 拷贝

    FAQ

    1
    Why choose a resistive and inductive load bank instead of a purely resistive load bank?
    A resistive and inductive load bank more accurately simulates real industrial loads such as motors, pumps, and HVAC equipment. This enables more realistic generator performance testing under actual operating conditions.
    2
    What is the advantage of 0.5kW and 0.5kVar load resolution?
    Fine load resolution allows engineers to precisely match target power levels, improving testing accuracy and providing smoother load adjustments during commissioning and acceptance testing.
    3
    What types of equipment can be tested?
    The SIRL-250L 250kVA is suitable for diesel generators, gas generators, UPS systems, transformers, power distribution equipment, BESS, and critical power infrastructure.
    4
    What electrical parameters can be monitored in real time?
    The integrated monitoring system displays voltage, current, frequency, active power (kW), reactive power (kVar), apparent power (kVA), and power factor (PF) in real time.
    5
    Does the load bank support remote operation?
    Yes. The system supports both local operation and PC-based remote control through Modbus TCP communication, allowing easy integration into automation platforms.
    6
    How does the load bank ensure operational safety?
    Multiple protection systems—including fan overload protection, low airflow detection, thermal shutdown, MCCB protection, local/remote interlock, and emergency stop—continuously monitor the operating status to ensure safe and reliable testing.
    7
    Can the load bank perform continuous full-load operation?
    Yes. The industrial cooling system and high-quality resistor elements are designed for continuous-duty operation, ensuring stable performance during extended testing periods.
    8
    Why is an integrated generator tester beneficial?
    The built-in 8961 F2 generator tester combines load control and electrical measurement into one platform, simplifying testing procedures while improving efficiency and data accuracy.
    9
    Is the load bank suitable for outdoor installation?
    Yes. The IP54 control compartment, IP55 enclosure, and industrial enclosure design provide reliable protection against dust and environmental conditions, making the unit suitable for both indoor and outdoor applications.
    10
    Which industries commonly use this product?
    The SIRL-250L 250kVA is widely used in generator manufacturing, power utilities, data centers, EPC contractors, electrical contractors, UPS manufacturers, BESS projects, industrial facilities, hospitals, airports, and other mission-critical power applications.
    11
    Typical product delivery time?
    6 weeks.
    12
    Warranty service?
    2 years.
    13
    Do you provide installation and testing support?
    Yes, Rata provides on-site testing services, including equipment installation, configuration, and data logging.
    14
    How many countries have you exported to?
    We export to over 80 countries worldwide.
    15
    Why choose us?
    We have ISO、CE certification and are Authorized factories for Siemens and Schneider Electric brands.
    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    Customer service
    detect