SIRL-5500L 5500kVA Resistive /Reactive Load Bank For Generator, UPS, Grid, and Renewable energy testing 1
SIRL-5500L 5500kVA Resistive /Reactive Load Bank For Generator, UPS, Grid, and Renewable energy testing 2
SIRL-5500L 5500kVA Resistive /Reactive Load Bank For Generator, UPS, Grid, and Renewable energy testing 3
SIRL-5500L 5500kVA Resistive /Reactive Load Bank For Generator, UPS, Grid, and Renewable energy testing 4
SIRL-5500L 5500kVA Resistive /Reactive Load Bank For Generator, UPS, Grid, and Renewable energy testing 5
SIRL-5500L 5500kVA Resistive /Reactive Load Bank For Generator, UPS, Grid, and Renewable energy testing 1
SIRL-5500L 5500kVA Resistive /Reactive Load Bank For Generator, UPS, Grid, and Renewable energy testing 2
SIRL-5500L 5500kVA Resistive /Reactive Load Bank For Generator, UPS, Grid, and Renewable energy testing 3
SIRL-5500L 5500kVA Resistive /Reactive Load Bank For Generator, UPS, Grid, and Renewable energy testing 4
SIRL-5500L 5500kVA Resistive /Reactive Load Bank For Generator, UPS, Grid, and Renewable energy testing 5

SIRL-5500L 5500kVA Resistive /Reactive Load Bank For Generator, UPS, Grid, and Renewable energy testing

SIRL-5500L combines 5500kVA high-capacity testing, true industrial load simulation, smart remote control, and industrial-grade protection into a single containerized solution.

It is an ideal choice for AI data centers, large generator testing, UPS commissioning, BESS validation, and power infrastructure projects requiring reliable full-load and power-factor testing.

5.0
Warranty time:
2 years
Delivery time:
8 weeks
ISO Certification:
ISO9001/ISO14001
Brand:
RATA
Factory Price:
Negotiate
Supply Ability:
200,000 Piece/Pieces per Month
Port:
Shanghai and Guangzhou are both available
Payment Terms:
L/C,Cash,Western Union,T/T, Paypal
Min.Order Quantity:
1 pcs
ODM & OEM:
Available
Certification:
CE 60204 Standard​
design customization

    oops...!

    no product data.

    Go to homepage
    SIRL-5500L Technical documentation
    SIRL-5500L Technical documentation

    Product Introduction

    The SIRL-5500L is a high-capacity Resistive / Inductive (R/L) Load Bank specifically designed for testing large diesel generators, UPS systems, data centers, power grids, and Battery Energy Storage Systems (BESS).


    The complete system is rated at 5500kVA and consists of two independent 2750kVA sections, which can operate separately or simultaneously to provide up to 4400kW resistive load and 3300kVar inductive load at a 0.8 power factor.


    With its containerized design, top-airflow cooling structure, and smart local/remote control system, the SIRL-5500L is ideal for factory acceptance testing (FAT), site commissioning, and long-duration reliability verification.

    1 (4) 拷贝

    Key Features and Advantages

    SIRL-5500L 5500kVA Resistive /Reactive Load Bank For Generator, UPS, Grid, and Renewable energy testing 7
    High-Capacity Resistive / Inductive Integration
    1 (18)
    Dual Independent 2750kVA Systems
    调节
    High-Precision Load Adjustment
    冷却
    Top Airflow Cooling Design
    2 拷贝
    Industrial-Grade Stainless Steel Load Elements
    系统
    Smart Control System
    SIRL-5500L 5500kVA Resistive /Reactive Load Bank For Generator, UPS, Grid, and Renewable energy testing 13
    Comprehensive Safety Protection
    箱式
    Containerized Construction

    ENCLOSURE DRAWINGS

    未标题-2 (19)
    未标题-2 (19)
    未标题-1 (28)
    未标题-1 (28)

    Main Parameters

     System A- Independent 2750kVA Section
    Active Power 2200kW
    Inductive Reactive Power 1650kvar
     System B- Independent 2750kVA Section
    Active Power 2200kW
    Inductive Reactive Power 1650kvar
    Total 5500kVA Load Bank System
    Apparent power 5500 kVA
    (2 × 2750 kVA load units)
    Active Power 4400kW
    Inductive Reactive Power 3300kvar
    Power factor 0.8
    Rated test voltage. 480Vac
    Hz. 60Hz.
    Phase & wires 3P3W (Delta)
    Active power load resolution 1kW
    Inductive power load resolution 1kVar
    Voltage Tolerance(Short Term Operation) +5%
    Load Element Tolerance ± 3%
    Load connection Copper busbars
    Control power Auxiliary
    Control voltage 480Vac

    Key details

    DJI_20260623_151113_695_副本 拷贝
    DJI_20260623_151113_695_副本 拷贝
    IMG_3405_副本 拷贝
    IMG_3405_副本 拷贝
    DJI_20260623_151122_365_副本 拷贝
    DJI_20260623_151122_365_副本 拷贝
    IMG_3413_副本 拷贝
    IMG_3413_副本 拷贝
    IMG_3440_副本 拷贝
    IMG_3440_副本 拷贝
    IMG_3418_副本 拷贝
    IMG_3418_副本 拷贝
    IMG_3446_副本 拷贝
    IMG_3446_副本 拷贝

    FAQ

    1
    Why does the 5500kVA load bank use two independent 2750kVA systems?
    The dual-system architecture provides redundancy, flexible capacity matching, and allows maintenance on one section without interrupting operation of the other section.
    2
    What are the advantages of a resistive/reactive load bank over a purely resistive load bank?
    It can simultaneously provide active and reactive power, more accurately simulating real industrial loads such as motors, pumps, and HVAC systems.
    3
    Why is a top-airflow design used?
    Top airflow improves heat dissipation, prevents hot-air recirculation, and is particularly suitable for containerized installations.
    4
    Why are Ni-Cr alloy elements used?
    Ni-Cr elements offer excellent high-temperature resistance, oxidation resistance, and long service life, with operating temperatures up to approximately 1200°C.
    5
    How is long-term safe operation ensured?
    The system includes fan overload protection, low-airflow protection, over-temperature protection, MCCB protection, local/remote interlock, and emergency stop circuits.
    6
    Does the load bank support remote control?
    Yes. It supports Modbus TCP communication via an RJ45 interface for integration with PLC and SCADA systems.
    7
    What is the load adjustment resolution?
    Both resistive and reactive loads have a minimum adjustment step of 1kW / 1kVar.
    8
    Why are tin-plated copper busbars used?
    Tin-plated busbars reduce contact resistance, improve current-carrying capacity, and enhance long-term reliability.
    9
    Which generator systems can be tested?
    Diesel generators, natural gas generators, gas turbines, and microgrid power systems.
    10
    Can different power factors be simulated?
    Yes. Independent control of resistive and inductive loads allows flexible power factor adjustment.
    11
    Why are 12 industrial blowers installed?
    The multi-fan configuration provides sufficient airflow (70m³/kW/h) to maintain safe operating temperatures during high-power testing.
    12
    What environments is the load bank suitable for?
    With IP55 control protection and IP54 enclosure protection, it is suitable for outdoor, high-temperature, and industrial environments.
    13
    How does the unit adapt to different voltages?
    The load bank operates at 480V and can also run at 410V and 380V with proportional power derating.
    14
    What are the benefits of the modular design?
    Modular resistors, contactors, fans, and fuses can be replaced quickly, reducing downtime and maintenance costs.
    15
    Which industries is this product most suitable for?
    Data centers, generator manufacturers, energy storage projects, EPC contractors, power utilities, oil & gas facilities, airports, hospitals, and other mission-critical infrastructure applications.
    16
    Typical product delivery time?
    At least 8 weeks.
    17
    Warranty service?
    2 years.
    18
    Do you provide installation and testing support?
    Yes, Rata provides on-site testing services, including equipment installation, configuration, and data logging.
    19
    How many countries have you exported to?
    We export to over 80 countries worldwide.
    20
    Why choose us?
    We have ISO、CE certification and are Authorized factories for Siemens and Schneider Electric brands.
    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    Customer service
    detect