DC 480V 50kW resistive load bank For UPS Testing

This RTLBS50L AC resistive load bank is a high-performance and high-reliability AC testing device.It is specially developed to meet the performance testing, capacity verification and maintenance demands of various AC power systems, including generator sets, UPS, inverters, transformers and other equipment.

5.0
Warranty time:
3 years
Delivery time:
4 weeks
ISO Certification:
ISO9001/ISO14001
Brand:
RATA
Factory Price:
Negotiate
Supply Ability:
200,000 Piece/Pieces per Month
Port:
Shanghai and Guangzhou are both available
Payment Terms:
L/C,Cash,Western Union,T/T, Paypal
Min.Order Quantity:
1 pcs
ODM & OEM:
Available
Certification:
CE 60204 Standard​
design customization

    oops...!

    no product data.

    Go to homepage
    Datasheet -50kw 480v 60hz-Rata load bank
    Datasheet -50kw 480v 60hz-Rata load bank

    Product Introduction

    The Rata  AC 50kW 480V resistive load bank offers these core advantages:

    RTLBS50L is a high-performance 50kW AC resistive load bank specifically designed for 480VAC/60Hz power systems.Adopting high-quality 8020 nichrome alloy resistors and 6 sets of high-air-volume axial flow fans, the unit delivers outstanding heat dissipation and reliable continuous operation.It features core advantages including a fine load step resolution of 1kW and overall system accuracy of ±3%. Equipped with an intuitive HMI touchscreen and an optional PLC remote control system, it enables real-time monitoring and data analysis of power parameters.


    Supported by comprehensive safety protection functions and a mobile caster design, it serves as an accurate, safe and intelligent testing solution for generator set performance verification, data center UPS testing and power capacity assessment.

    0 (5)

    Structure drawing

    1 (112)
    1 (112)
    2 (88)
    2 (88)
    3 (61)
    3 (61)
    4 (45)
    4 (45)

    Key Features and Advantages

    IMG_8214 拷贝
    Rugged and durable design with excellent heat dissipation performance
    DC  480V 50kW resistive load bank For UPS Testing 13
    Convenient operation and intelligent control
    0 (4)
    Multiple safety protection mechanisms
    DC  480V 50kW resistive load bank For UPS Testing 15
    Outstanding portability

    Key details

    IMG_9585 拷贝
    IMG_9585 拷贝
    IMG_9818 拷贝
    IMG_9818 拷贝
    IMG_8600 拷贝
    IMG_8600 拷贝
    IMG_8598 拷贝
    IMG_8598 拷贝
    IMG_8596 拷贝
    IMG_8596 拷贝
    IMG_8595 拷贝
    IMG_8595 拷贝
    IMG_8594 拷贝
    IMG_8594 拷贝
    IMG_8592 拷贝
    IMG_8592 拷贝

    Main Parameters

    Model No. RTLBS50L
    Country of origin China
    Rated testing voltage 480Vac
    Control voltage (Auxiliary power supply) 120V- 280V  1Ph
    Frequency 60Hz
    Phases & Wires 3P4W
    Load step resolution 1kW
    Active load steps (kW) 1kw+2kw*2+5kw+10kw*2pcs+20kw
    Estimated Length*Width*Height(mm) 731*657*1034mm
    Fans Nos.& Airflow volume 6* 410CFM/H
    Estimated Weight (kg) 220kg
    Other information
    Whole machine accuracy ±3%
    Voltage Tolerance (Short Term Operation) ±5%
    Load Element Tolerance ≤+2.5%
    Load Connections Copper terminal
    Protection Thermal emergency cut out
    Air flow switch
    Fan overload protection
    Emergency stop
    Airflow direction Horizontal air forced cooling
    Fan type Airfoil axial fan
    Load switching contactor type AC contactors
    Rated maximum/minimum ambient temp. operation +50°C / -20°C
    Altitude rating ≤2000 [m.a.s.l]
    Control chamber IP rating IP 23 indoor
    Enclosure material Cold rolled steel plate with painting.
    Enclosure color RAL 7035 or customized
    Portability 4 Casters
    Certificates ISO9001:2015,ISO14001:2015,ISO45001:2018,CE
    Duty cycle Continuous
    Resistor
    Resistor material finned resistor, AISI304/stamped elements
    8020 Ni-Cr alloy
    Stainless steel tube filled with magnesium oxide powder
    Insulation Test voltage 2000 Vac for 1min
    Withstand temperature About 800℃
    Resistance error ± 3%
    Main parts brands
    Main parts brands Contactor: Schneider or equivalent
    Relay: CHINT or equivalent
    Fuse: Delixi or equivalent
    Emergency stop: Schneider
    Load bank control system 1
    Manual control HMI touch screen
    Load bank control system 2 (optional)
    PLC control Remote PC control with patented software Nexus-1
    Support printing Table saved by Excel,curve saved by word.
    Remote computer automatic control Mod Bus TCP or RS485 communication protocol
    Control software in English version(commissioning well before sent to user)
    Siemens PLC system
    Function include load data monitor, acquisition, curve, chart, load data save and printing.
    Quality warranty
    12 months start from the day receiving the goods at your side.
    Services
    7×24 hours service(subject to time zone difference)
    Online meeting available anytime.
    Technician guidance online freely, technician going abroad in charged(negotiable).
    Documents providing
    Factory report.
    Operation and maintenance instructions.
    Structure diagrams & Electrical schematic diagram after deposit.

    FAQ

    1
    Is the RTLBS50L load bank suitable for testing different types of generator sets, such as diesel generators and gas generators?
    Yes. The RTLBS50L is a universal AC resistive load bank, applicable to various AC generator sets, including diesel generators, gas generators, turbine generators and more. Designed for a rated voltage of 480VAC and a frequency of 60Hz, it complies with power grid standards in North America and parts of Asia, and is widely used for performance verification of different generator units.
    2
    In generator testing, how to precisely control the load to simulate various operating conditions?
    The RTLBS50L supports manual operation via an intuitive HMI touchscreen for direct load adjustment. In addition, the optional PLC control system enables remote PC control through Modbus TCP or RS485 protocol. Combined with the patented Nexus-1 software, it realizes real-time load data monitoring, collection, curve display, data storage and printing. With a load step resolution of 1kW, it allows fine load regulation to simulate generator performance under multiple working conditions, including startup, step loading, full load and unloading.
    3
    How suitable is this load bank for outdoor generator testing and data center applications?
    Featuring a rugged build, the RTLBS50L adopts a painted cold-rolled steel shell and is fitted with 4 casters for excellent mobility. Its rated operating temperature ranges from -20°C to +50°C, and the control section features IP23 indoor protection rating. For outdoor deployment, proper rainproof and dustproof measures are recommended to ensure long-term stable operation of the equipment.
    4
    What core equipment in data centers can this 50kW AC load bank be used to test?
    The RTLBS50L AC load bank is mainly used for the testing of AC power systems in data centers, including UPS (Uninterruptible Power Supply) systems, PDU (Power Distribution Units), standby generator sets, and computer room power capacity verification.
    5
    Typical product delivery time?
    4 weeks.
    6
    Warranty service?
    3 years.
    7
    How to integrate this load bank with data center monitoring systems to realize remote control and data recording?
    The RTDCS50M supports remote connection and control via RJ45 Ethernet port. Operators can remotely control, monitor and record operating data of the load bank through dedicated PC software.
    8
    Do you provide installation and testing support?
    Yes, Rata provides on-site testing services, including equipment installation, configuration, and data logging.
    9
    How many countries have you exported to?
    We export to over 80 countries worldwide.
    10
    Why choose us?
    We have ISO、CE certification and are Authorized factories for Siemens and Schneider Electric brands.
    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    Customer service
    detect