This RTDCS50M DC load bank is specially developed to meet the discharge testing, capacity verification and maintenance requirements of various DC power supply systems, including battery packs, DC generators, rectifiers, DC UPS systems and more.

5.0
Warranty time:
3 years
Delivery time:
4 weeks
ISO Certification:
ISO9001/ISO14001
Brand:
RATA
Factory Price:
Negotiate
Supply Ability:
200,000 Piece/Pieces per Month
Port:
Shanghai and Guangzhou are both available
Payment Terms:
L/C,Cash,Western Union,T/T, Paypal
Min.Order Quantity:
1 pcs
ODM & OEM:
Available
Certification:
CE 60204 Standard​
design customization

    oops...!

    no product data.

    Go to homepage
    Datasheet -50VDC 1000A 50kw DC load bank
    Datasheet -50VDC 1000A 50kw DC load bank

    Product Introduction

    The Rata DC50V 1000A 50kW Load Bank offers these core advantages:

    The RTDCS50M is a high-performance 50kW DC load bank specially designed for DC power supply systems, with powerful testing capacity of 50VDC/1000A.

    Equipped with high-quality nichrome finned resistors and a forced air cooling system, the equipment maintains stable and reliable operation under continuous working conditions.


    It features core advantages including high load accuracy of ±1% and fine step resolution of 1A. Combined with an HMI touch screen and RJ45 remote control, it can accurately simulate various complex operating conditions.


    With multiple safety protection mechanisms and a portable caster design, it serves as an ideal professional and user-friendly testing tool for generator set verification, data center battery discharge, UPS maintenance and other application scenarios.

    IMG_9809 2 拷贝 (2)

    Key Features and Advantages

    IMG_8214 拷贝
    Rugged and durable design with excellent heat dissipation performance
    DC50V 1000A 50kW Load Bank For UPS Testing 8
    Convenient operation and intelligent control
    0 (4)
    Multiple safety protection mechanisms
    DC50V 1000A 50kW Load Bank For UPS Testing 10
    Outstanding portability

    Key details

    IMG_9555 拷贝
    IMG_9555 拷贝
    IMG_9563 拷贝
    IMG_9563 拷贝
    IMG_9564 拷贝
    IMG_9564 拷贝
    IMG_9598 拷贝
    IMG_9598 拷贝
    IMG_9599 拷贝
    IMG_9599 拷贝
    IMG_9601 拷贝
    IMG_9601 拷贝

    Main Parameters

    Model No. RTDCS50M
    Country of origin China
    Auxiliary power supply 120V, 280V 60Hz
    Rated Testing Voltage 50V DC
    Rated power 50kw
    Rated Current 1000A
    Load accuracy ±1%
    Load step resolution 1A
    Active load steps (kw) 1A-1000A adjustable
    Estimated Width(mm)*Depth(mm)*Height(mm) 877mm*750mm*853mm
    Estimated weight 190kg
    Other information
    Load Connections Quick connectors
    Protection Thermal emergency cut out
    Fan switch
    Fan overload protection
    Emergency stop
    Airflow direction Horizontal air forced cooling
    Fan type Airfoil axial fan
    Load switching contactor type DC contactors
    Rated minimum / maximum ambient temp. operation -15°C to +50°C
    Altitude rating ≤2000 [m.a.s.l]
    Control chamber IP rating IP 23 Indoor
    Enclosure material Cold rolled steel plate with painting.
    Enclosure color RAL 7035
    Resistor material finned resistor, AISI304/stamped elements
    8020 Ni-Cr alloy
    Resistance error 1.5%~± 3%
    Portability Casters and hand folders
    Certificates ISO9001:2015,ISO14001:2015,ISO45001:2018,CE
    Duty cycle Continuous
    Load bank control system
    Manual control Press buttons or touch screen
    Quality warranty
    12 months start from receiving the goods at your side.
    Services
    Online meeting available
    Documents providing
    Factory report. & Operation manual.
    Operation and maintenance instructions.

    FAQ

    1
    What key equipment in data centers can this 50kW DC load bank be used to test?
    The RTDCS50M DC load bank is mainly applied to the testing of DC power systems in data centers, including:
    UPS battery packs: Conduct discharge tests to evaluate battery capacity, health status and backup duration.
    DC PDU: Verify the output capacity and operational stability of DC power distribution units.
    Rectifiers: Test the output power, voltage stability and overload resistance of rectifier modules.
    Server DC power supplies: Perform performance verification on DC-powered server power modules.
    2
    Data centers require high precision for testing equipment. Can this load bank meet the standard?
    The RTDCS50M load bank features high load accuracy of ±1% and 1A load step resolution. It can accurately restore the actual DC load of data center hardware, ensuring highly precise and reliable test results for core indicators such as battery capacity and power system efficiency, fully meeting the high-precision testing requirements of data centers.
    3
    How to ensure operational safety during battery discharge tests in data centers?
    The load bank is equipped with multi-layer safety protections, including thermal emergency cut-off, fan overload protection and emergency stop button.
    4
    Long-term continuous testing is commonly required in data centers. Does this load bank support continuous operation?
    Yes. The RTDCS50M is designed for continuous duty cycle operation. Its high-efficiency horizontal forced air cooling system and high-grade resistance materials ensure long-term stable continuous operation, fully meeting the demand of multi-hour or extended-cycle battery discharge tests in data centers.
    5
    Typical product delivery time?
    4 weeks.
    6
    Warranty service?
    3 years.
    7
    How to integrate this load bank with data center monitoring systems to realize remote control and data recording?
    The RTDCS50M supports remote connection and control via RJ45 Ethernet port. Operators can remotely control, monitor and record operating data of the load bank through dedicated PC software.
    8
    Do you provide installation and testing support?
    Yes, Rata provides on-site testing services, including equipment installation, configuration, and data logging.
    9
    How many countries have you exported to?
    We export to over 80 countries worldwide.
    10
    Why choose us?
    We have ISO、CE certification and are Authorized factories for Siemens and Schneider Electric brands.
    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    Customer service
    detect