In the communication industry, power supply is usually compared to the heart of communication system. The management departments of communication operators have paid attention to the maintenance of communication power supply from the perspective of ensuring quality, production safety and property safety.
Rata is creatively designed to help customers break into the fast-growing market.
PRODUCT OVERVIEW
In the communication industry, power supply is usually compared to the heart of communication system. The management departments of communication operators have paid attention to the maintenance of communication power supply from the perspective of ensuring quality, production safety and property safety. According to the latest investigation of many grass-roots maintenance staff, At present, the common maintenance technical problem in the maintenance of communication power supply is that the detection of output power and load capacity of various generators and UPS equipment has not been carried out effectively and smoothly. Rata 150KW load bank can accurately test the output power and load capacity of various generator sets and UPS equipment, The randomly equipped analysis software can record various data changes in the whole test process and automatically generate test reports, which is convenient to establish management files of equipment operation status.
Prominent applications of 150KW load bank include:
Test the output power and load capacity of UPS equipment
During the project acceptance of newly installed UPS equipment, check whether the output power of UPS equipment and battery can meet the design requirements.
Daily maintenance and routine inspection of UPS equipment. According to the requirements of the newly issued communication power supply maintenance regulations, UPS equipment shall be inspected every year
Conduct checking discharge test
Test the output power and load capacity of diesel generator
Check whether the newly installed diesel generator can meet the design requirements during the project acceptance
After the diesel generator is equipped with noise reduction equipment such as muffler, check whether its output power can meet the operation needs of communication equipment.
After the diesel generator is repaired, check whether its output power, load capacity and other performance indexes meet the requirements
Daily maintenance and routine inspection of diesel generator. According to the newly issued maintenance regulations of communication power supply, the diesel generator shall be loaded and tested for 15-30 minutes every half a year.
Test the output power and load capacity of communication AC equipment such as AC voltage regulator, inverter and switching power supply
The main functions of dry load bank, load resistance bank and adjustable resistance Bank: the test data of important parameters such as power, voltage, current, frequency and temperature can be seen at a glance to help users effectively carry out scientific acceptance of UPS, generator and other AC equipment.
The high-precision measurement function makes the test report more authoritative and the equipment management archives more scientific.
Backlit LCD display, displaying various parameters and real-time test data.
Constant power discharge value can be set (no segment type). All high-efficiency electric heating elements meet UL safety specifications
With fan fault detection, overvoltage, overcurrent, leakage and other protection functions
It can discharge multiple parts in parallel to adapt to the occasion of high current discharge
Chinese window interface display, simple operation, with USB, RS232 and RS485 communication interfaces, can be connected with PC for control, and display voltage, current and other parameter curves and tables
The host has built-in memory, and the storage records can be read with USB flash disk. A single machine can work without carrying a computer; You can print the report by computer in the future
With voltage and current calibration and correction function, the measured value of the instrument can be calibrated and corrected at any time to ensure the measurement accuracy
With power down saving function. All test data will not be lost after power failure. Continue to work after power on to prevent accidental power failure and obtain complete test results
With data analysis software, analyze and print the discharge curve, automatically generate the test report, and can be exported to excel
Discharge termination voltage can be set
Discharge termination time can be set
PRODUCT PICTURE
APPLICATION SCENARIO
PARTIAL PARAMETERS
Note: all parameters are for reference only and can be customized | |
Product name | 150kW load bank |
Specifications | R150kW/400V/50Hz |
Formation | One load bank(Including dry resistance load, electrical control components, measurement and control system) |
Load step | According to customer needs |
Load connection | Copper bar |
Resistor | Each resistance element: insulation impedance DC1000V/100MΩ above Withstand voltage ac 2000v for 5min Resistance error of each resistance tube:±3% |
Load control | Local manual control, local automatic control or remote automatic control can be selected |
Loading accuracy | Less than or equal to 3% |
Three phase balance | Unbalance degree less than or equal to 3% |
Minimum step | 1kW |
Working mode | Continuous work |
Load protection | Short circuit, overcurrent, high temperature, fan fault protection |
External power | TN-C,380V/50Hz |
Cooling mode | Forced air cooling, side air outlet or top air outlet |
Insulation class | F |
Measurement accuracy | The display accuracy is 0.5,the sampling accuracy is 0.2 |
Electrical parameter display | Three phase voltage, three-phase current, frequency, power, etc |
Load expansion | Parallel expansion of multiple load containers |
Standard | Meet international standard, ship standard, military standard and telecommunication standard |
Transport | The load bank has a load-bearing lifting hole, which meets the requirements of long-distance transportation |
Color | Customized |
Ambient temperature | -20℃ to 50℃ |
Humidity | Up to 100% |
Altitude | Up to 2500m |
Atmospheric pressure | 86 to 106kPa |
MORE SPECIFICATIONS
Note: all parameters are for reference only and can be customized | ||||
Power(kW) | Voltage(kV) | Frequency(Hz) | Size(mm,L*W*H) | Weight(Kg) |
Low voltage | ||||
100 | 0.4 | 50 | 1100*900*1000 | 320 |
200 | 0.4 | 50 | 1350*1100*1100 | 450 |
300 | 0.4 | 50 | 1500*1200*1200 | 650 |
400 | 0.4 | 50 | 1700*1500*1500 | 830 |
500 | 0.4 | 50 | 1700*1600*1600 | 950 |
600 | 0.4 | 50 | 1800*1600*1600 | 1150 |
800 | 0.4 | 50 | 1900*1800*1700 | 1900 |
1000 | 0.4 | 50 | 2300*1700*2100 | 2100 |
1200 | 0.4 | 50 | 2500*1800*2200 | 2300 |
1500 | 0.4 | 50 | 2500*1860*2300 | 2600 |
1800 | 0.4 | 50 | 3000*2000*2300 | 4000 |
2000 | 0.4 | 50 | 3000*2000*2300 | 5000 |
2500 | 0.4 | 50 | 4000*2438*2500 | 6000 |
3000 | 0.4 | 50 | 6000*2438*2500 | 7000 |
Medium voltage | ||||
1000 | 6/10.5 | 50/60 | 3000*2438*2500 | 3500 |
1200 | 6/10.5 | 50/60 | 4000*2438*2500 | 3900 |
1500 | 6/10.5 | 50/60 | 4000*2438*2500 | 4500 |
1600 | 6/10.5 | 50/60 | 5000*2438*2500 | 5000 |
1800 | 6/10.5 | 50/60 | 5000*2438*2500 | 6500 |
2000 | 6/10.5 | 50/60 | 6000*2438*2500 | 7500 |
2200 | 6/10.5 | 50/60 | 6000*2438*2500 | 8000 |
2500 | 6/10.5 | 50/60 | 6000*2438*2500 | 10000 |
3000 | 6/10.5 | 50/60 | 7000*2438*2500 | 12000 |
4000 | 6/10.5 | 50/60 | 8000*2438*2500 | 14000 |
5000 | 6/10.5 | 50/60 | 9000*2438*2500 | 15000 |
6000 | 6/10.5 | 50/60 | 12000*2438*2500 | 16000 |
7000 | 6/10.5 | 50/60 | 12000*2438*2500 | 17000 |
8000 | 6/10.5 | 50/60 | 12000*2438*2500 | 18000 |
TRANSPORT AND INSTALL
The top four corners of the load bank are provided with lifting holes and the bottom four corners are provided with rollers to facilitate loading, transportation and mobile installation.
COMPANY PROFILE
Deyang Rata Technology Co., Ltd., established in 2013, is located in Jinshan Industrial Park, Luojiang District, Deyang City. Rata is an ISO9001:2012 quality management system certification enterprise and a national high-tech enterprise. Since its establishment, Rata has obtained 16 utility model patent certificates and 8 computer software copyright registration certificates.
Rata's main products include high and low voltage resistive load banks, resistive reactive load banks, rack mounted load banks, electronic loads and battery dischargers, etc. the products are mainly used in large shipyards and power plants at home and abroad, generator on load test operation, transformer test, UPS power supply test and storage battery discharge point test, etc. In addition, Rata provides users with perfect system solutions such as ship shore power, data center, new energy and grid adaptability experiment.
Rata has a perfect technological innovation system and strong R & D capability. For many years, it adheres to the policy of "quality first, customer first", and serves all major fields at home and abroad in good faith. The product quality is reliable and the price is reasonable, which is deeply favored by the majority of users.
HONORARY QUALIFICATION
Since its establishment, Rata has obtained 16 utility model patent certificates and 8 computer software copyright registration certificates, and has been recognized as a national high-tech enterprise.
Rata is quite attractive with its design.