In the communication industry, the power supply is usually compared to the heart of the communication system. The management departments of communication operators have paid attention to the maintenance of communication power supply from the perspective of ensuring quality, production safety, and property safety.
product introduction
Rata 150KW load bank can accurately test the output power and load capacity of various generator sets and UPS equipment, The randomly equipped analysis software can record various data changes in the whole test process and automatically generate test reports, which is convenient to establish management files of equipment operation status.
Prominent applications of 150KW load bank include:
Test the output power and load capacity of UPS equipment;
During the project acceptance of newly installed UPS equipment, check whether the output power of UPS equipment and battery can meet the design requirements.Daily maintenance and routine inspection of UPS equipment.
more product specification
| Product name | 150kW load bank |
| Specifications | R150kW/400V/50Hz |
| Formation | One load bank(Including dry resistance load, electrical control components, measurement and control system) |
| Load step | According to customer needs |
| Load connection | Copper bar |
| Resistor | Each resistance element: insulation impedance DC1000V/100MΩ above; Withstand voltage ac 2000v for 5min; Resistance error of each resistance tube:±3%; |
| Load control | Local manual control, local automatic control or remote automatic control can be selected |
| Loading accuracy | Less than or equal to 3% |
| Three phase balance | Unbalance degree less than or equal to 3% |
| Minimum step | 1kW |
| Working mode | Continuous work |
| Load protection | Short circuit, overcurrent, high temperature, fan fault protection |
| External power | TN-C,380V/50Hz |
| Cooling mode | Forced air cooling, side air outlet or top air outlet |
| Insulation class | F |
| Measurement accuracy | The display accuracy is 0.5,the sampling accuracy is 0.2 |
| Electrical parameter display | Three phase voltage, three-phase current, frequency, power, etc |
| Load expansion | Parallel expansion of multiple load containers |
| Standard | Meet international standard, ship standard, military standard and telecommunication standard |
| Transport | The load bank has a load-bearing lifting hole, which meets the requirements of long-distance transportation |
| Color | Customized |
| Ambient temperature | -20℃ to 50℃ |
| Humidity | Up to 100% |
| Altitude | Up to 2500m |
| Atmospheric pressure | 86 to 106kPa |