loading
150kw Load Bank 1
150kw Load Bank 2
150kw Load Bank 3
150kw Load Bank 1
150kw Load Bank 2
150kw Load Bank 3

150kw Load Bank

In the communication industry, power supply is usually compared to the heart of communication system. The management departments of communication operators have paid attention to the maintenance of communication power supply from the perspective of ensuring quality, production safety and property safety.

    oops...!

    no product data.

    Go to homepage

    Rata is creatively designed to help customers break into the fast-growing market.

    1


    PRODUCT OVERVIEW


    In the communication industry, power supply is usually compared to the heart of communication system. The management departments of communication operators have paid attention to the maintenance of communication power supply from the perspective of ensuring quality, production safety and property safety. According to the latest investigation of many grass-roots maintenance staff, At present, the common maintenance technical problem in the maintenance of communication power supply is that the detection of output power and load capacity of various generators and UPS equipment has not been carried out effectively and smoothly. Rata 150KW load bank can accurately test the output power and load capacity of various generator sets and UPS equipment, The randomly equipped analysis software can record various data changes in the whole test process and automatically generate test reports, which is convenient to establish management files of equipment operation status.

    Prominent applications of 150KW load bank include:

    Test the output power and load capacity of UPS equipment

    During the project acceptance of newly installed UPS equipment, check whether the output power of UPS equipment and battery can meet the design requirements.

    Daily maintenance and routine inspection of UPS equipment. According to the requirements of the newly issued communication power supply maintenance regulations, UPS equipment shall be inspected every year

    Conduct checking discharge test

    Test the output power and load capacity of diesel generator

    Check whether the newly installed diesel generator can meet the design requirements during the project acceptance

    After the diesel generator is equipped with noise reduction equipment such as muffler, check whether its output power can meet the operation needs of communication equipment.

    After the diesel generator is repaired, check whether its output power, load capacity and other performance indexes meet the requirements

    Daily maintenance and routine inspection of diesel generator. According to the newly issued maintenance regulations of communication power supply, the diesel generator shall be loaded and tested for 15-30 minutes every half a year.

    Test the output power and load capacity of communication AC equipment such as AC voltage regulator, inverter and switching power supply

    The main functions of dry load bank, load resistance bank and adjustable resistance Bank: the test data of important parameters such as power, voltage, current, frequency and temperature can be seen at a glance to help users effectively carry out scientific acceptance of UPS, generator and other AC equipment.

    The high-precision measurement function makes the test report more authoritative and the equipment management archives more scientific.

    Backlit LCD display, displaying various parameters and real-time test data.

    Constant power discharge value can be set (no segment type). All high-efficiency electric heating elements meet UL safety specifications

    With fan fault detection, overvoltage, overcurrent, leakage and other protection functions

    It can discharge multiple parts in parallel to adapt to the occasion of high current discharge

    Chinese window interface display, simple operation, with USB, RS232 and RS485 communication interfaces, can be connected with PC for control, and display voltage, current and other parameter curves and tables

    The host has built-in memory, and the storage records can be read with USB flash disk. A single machine can work without carrying a computer; You can print the report by computer in the future

    With voltage and current calibration and correction function, the measured value of the instrument can be calibrated and corrected at any time to ensure the measurement accuracy

    With power down saving function. All test data will not be lost after power failure. Continue to work after power on to prevent accidental power failure and obtain complete test results

    With data analysis software, analyze and print the discharge curve, automatically generate the test report, and can be exported to excel

    Discharge termination voltage can be set

    Discharge termination time can be set


    PRODUCT PICTURE



    150kw Load Bank 5


    APPLICATION SCENARIO


    150kw Load Bank 6


    PARTIAL PARAMETERS



    Note: all parameters are for reference only and can be customized

    Product name

    150kW load bank

    Specifications

    R150kW/400V/50Hz

    Formation

    One load bank(Including dry resistance load, electrical control components, measurement and control system)

    Load step

    According to customer needs

    Load connection

    Copper bar

    Resistor

    Each resistance element: insulation impedance DC1000V/100MΩ above

    Withstand voltage ac 2000v for 5min

    Resistance error of each resistance tube:±3%

    Load control

    Local manual control, local automatic control or remote automatic control can be selected

    Loading accuracy

    Less than or equal to 3%

    Three phase balance

    Unbalance degree less than or equal to 3%

    Minimum step

    1kW

    Working mode

    Continuous work

    Load protection

    Short circuit, overcurrent, high temperature, fan fault protection

    External power

    TN-C,380V/50Hz

    Cooling mode

    Forced air cooling, side air outlet or top air outlet

    Insulation class

    F

    Measurement accuracy

    The display accuracy is 0.5,the sampling accuracy is 0.2

    Electrical parameter display

    Three phase voltage, three-phase current, frequency, power, etc

    Load expansion

    Parallel expansion of multiple load containers

    Standard

    Meet international standard, ship standard, military standard and telecommunication standard

    Transport

    The load bank has a load-bearing lifting hole, which meets the requirements of long-distance transportation

    Color

    Customized

    Ambient temperature

    -20℃ to 50℃

    Humidity

    Up to 100%

    Altitude

    Up to 2500m

    Atmospheric pressure

    86 to 106kPa


    MORE SPECIFICATIONS



    Note: all parameters are for reference only and can be customized

    Power(kW)

    Voltage(kV)

    Frequency(Hz)

    Size(mm,L*W*H)

    Weight(Kg)

    Low voltage

    100

    0.4

    50

    1100*900*1000

    320

    200

    0.4

    50

    1350*1100*1100

    450

    300

    0.4

    50

    1500*1200*1200

    650

    400

    0.4

    50

    1700*1500*1500

    830

    500

    0.4

    50

    1700*1600*1600

    950

    600

    0.4

    50

    1800*1600*1600

    1150

    800

    0.4

    50

    1900*1800*1700

    1900

    1000

    0.4

    50

    2300*1700*2100

    2100

    1200

    0.4

    50

    2500*1800*2200

    2300

    1500

    0.4

    50

    2500*1860*2300

    2600

    1800

    0.4

    50

    3000*2000*2300

    4000

    2000

    0.4

    50

    3000*2000*2300

    5000

    2500

    0.4

    50

    4000*2438*2500

    6000

    3000

    0.4

    50

    6000*2438*2500

    7000

    Medium voltage

    1000

    6/10.5

    50/60

    3000*2438*2500

    3500

    1200

    6/10.5

    50/60

    4000*2438*2500

    3900

    1500

    6/10.5

    50/60

    4000*2438*2500

    4500

    1600

    6/10.5

    50/60

    5000*2438*2500

    5000

    1800

    6/10.5

    50/60

    5000*2438*2500

    6500

    2000

    6/10.5

    50/60

    6000*2438*2500

    7500

    2200

    6/10.5

    50/60

    6000*2438*2500

    8000

    2500

    6/10.5

    50/60

    6000*2438*2500

    10000

    3000

    6/10.5

    50/60

    7000*2438*2500

    12000

    4000

    6/10.5

    50/60

    8000*2438*2500

    14000

    5000

    6/10.5

    50/60

    9000*2438*2500

    15000

    6000

    6/10.5

    50/60

    12000*2438*2500

    16000

    7000

    6/10.5

    50/60

    12000*2438*2500

    17000

    8000

    6/10.5

    50/60

    12000*2438*2500

    18000


    TRANSPORT AND INSTALL



    image011

    The top four corners of the load bank are provided with lifting holes and the bottom four corners are provided with rollers to facilitate loading, transportation and mobile installation.


    COMPANY PROFILE



    150kw Load Bank 8

    Deyang Rata Technology Co., Ltd., established in 2013, is located in Jinshan Industrial Park, Luojiang District, Deyang City. Rata is an ISO9001:2012 quality management system certification enterprise and a national high-tech enterprise. Since its establishment, Rata has obtained 16 utility model patent certificates and 8 computer software copyright registration certificates.

    Rata's main products include high and low voltage resistive load banks, resistive reactive load banks, rack mounted load banks, electronic loads and battery dischargers, etc. the products are mainly used in large shipyards and power plants at home and abroad, generator on load test operation, transformer test, UPS power supply test and storage battery discharge point test, etc. In addition, Rata provides users with perfect system solutions such as ship shore power, data center, new energy and grid adaptability experiment.

    Rata has a perfect technological innovation system and strong R & D capability. For many years, it adheres to the policy of "quality first, customer first", and serves all major fields at home and abroad in good faith. The product quality is reliable and the price is reasonable, which is deeply favored by the majority of users.


    HONORARY QUALIFICATION


    Since its establishment, Rata has obtained 16 utility model patent certificates and 8 computer software copyright registration certificates, and has been recognized as a national high-tech enterprise.


    150kw Load Bank 9


    Rata is quite attractive with its design.

    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    no data
    Customer service
    detect