Rata 2000kW AC dummy load bank is a special equipment for detecting medium voltage power supply. It can directly measure the medium voltage power supply without going through the transformer.
Known for its high tolerance, it is highly regarded in the market.
OEM/ODM
Rata supply OEM/ODM service. Customized design,logo and color.
After Sales Service
Rata supply 7×24 hours after sales service,quick response.
Certificates
Located in 27 cities around the world,with 50 delivery centers, 7x24 hours delivery capacity,is the best partner for enterprise globalization
Partners
ABB,Schneider,Omron,Siemens Phoenix Contact, Delixi
Rata 2000kW(2MW)/6000VAC resistive load bank designed as container type and used for oil field generator load test. Based on the water and dust requirement,the protection include the air intake and air outlet,local panel,load bank enclosure painting.
This load bank can be operated by local panel switches and remote PC with operation software,communication protocol is Mod Bus TCP, commnucation interface for load bank and remote PC is RJ45,it also can be RS485 and RS232 based on clients' requirement.
Forced air cooling design. Air intake side with cover and steel mesh,the hole is 1cm²,the cover can be opened when load bank is working,and closed when load bank not working;air duct used for hot air outlet,it has the function for water proof and easily installed by bolts and nuts.
Load bank protection include high temperature alarm,low air volume alarm,fan interlock,over voltage and current,short circuit,smoke alarm,temperature and humidity control,access control and emergency stop.
Rated power capacity | 2000KW,resistive only |
Rated voltage | 6000VAC,3 phase 3 wire,connected with tin plated copper bar |
Control voltage | 380VAC,3 phase 4 wire,connected with terminal |
Design | Container design for outdoor use,IP54 rating |
Control mode | Local panel switching control +remote PC control,Siemens PLC system,RJ45 communication interface,load data save and pringting,operation software language can be user's local language |
Digital meter | Show voltage,current,power,power factor and frequency |
Load steps | 50kW+50kW+100kW+100kW+200kW+500kW+500kW+500kW |
Resistor | 8020 Ni-Cr alloy finned resistors |
Cooling | Forced air cooling,horizontal air intake and vertical hot air outlet with air duct |
Protection | High temperature,low air volume,phase sequence,short circuit,fan interlock,access control,smoke alarm,temperature and humidity control,emergency stop |
Movement | Hoisting,4 lift lugas on the top the local bank enclosure |
Size | 4500*2530*2600mm |
Weight | 6500kgs |
Packing | Wrapping film for export delivery |
Rata supply factory acceptance test service for the load bank if required. We will arrange the food and accomdation for your coming. We also supply free training service for the load bank operation during the visitation.
Wrapping film will be used for container type load bank packing for water proof.Generally export from Shanghai port by Sea.
For years, has went on the Rata market in an invincible position.
Product name |
2000kW resistive load bank; |
Model number | RT2000kWLB; |
Design | Container type with air duct for outdoor use; |
Rated power |
AC6kV. Connected with tin plated copper bar. |
Control power |
AC380V,3 phase 4 wire,connected with terminal; |
Frequency | 50Hz/60Hz; |
Loading accuracy | ≤ 3%; |
3 phase balance | Unbalance degree ≤ 3%; |
Duty cycle | Continuous work |
Insulation | F |
Operation mode |
Local panel switching control +remote PC control,Siemens PLC system,RJ45 communication interface,load data save and pringting,operation software language can be user's local language |
Load steps |
50kW resolution.50kW+50kW+100kW+100kW+200kW+500kW+500kW+500kW |
Resistor |
8020 Ni-Cr alloy finned resistor; |
Cooling system |
Forced air cooling;horizontal air intake and vertical outlet with air duct;Axial fan,noise less than 80dB at 3m distance; |
Enclosure | Q235 steel,powder coated. |
Protection |
High temperature,low air volume,phase sequence,short circuit,fan interlock,access control,smoke alarm,temperature and humidity control,emergency stop; |
Digital meter |
Voltage,current,power,power factor and frequency; |
Load expansion |
Parallel expansion of multiple loads; |
Standard |
Meet international standard,ship standard,military standard and telecommunication standard |
Movement |
Hoisting,4 lift lugas on the top the local bank enclosure |
Color |
Customized color |
Dimensions | 4500mm*2530mm*2600mm (L*W*H) |
Weight | 6500Kg |
Ambient temperature |
-20℃ to 50℃ |
Humidity |
Up to 100% |
Altitude |
Up to 2500m |
Atmospheric pressure |
86 to 106kPa |
Warranty period | 12 months start from commissioning at clients' ste |
Packing | Wrapping film |