RM‑6 is a 6 kW rack‑mount resistive load bank designed for low‑power equipment test scenarios. Adopting a 6U Rack‑Mount form factor, it supports dual‑channel single‑phase AC230 V input with a maximum 3 kW per channel and a total rated power of 6 kW.

By combining 0.5 kW, 1 kW and 1.5 kW load units, the equipment achieves fine loading steps of 0.5 kW. It is suitable for performance verification, factory inspection and maintenance testing of small‑scale generators, UPS units, power modules, inverters and other AC power‑supply devices.

5.0
Warranty time:
2 years
Delivery time:
6 weeks
ISO Certification:
ISO9001/ISO14001
Brand:
RATA
Factory Price:
Negotiate
Supply Ability:
200,000 Piece/Pieces per Month
Port:
Shanghai and Guangzhou are both available
Payment Terms:
L/C,Cash,Western Union,T/T, Paypal
Min.Order Quantity:
1 pcs
ODM & OEM:
Available
Certification:
CE 60204 Standard​
design customization

    oops...!

    no product data.

    Go to homepage
    RM-6_Datasheet_Z 7
    RM-6_Datasheet_Z 7

    Product Introduction

    The RM‑6 6 kW Rack‑Mount Resistive Load Bank is a compact load‑testing device purpose‑built for testing low‑power AC power‑supply equipment. It features a 6U rack‑mount form factor and supports dual‑channel single‑phase AC230 V input with a total rated power of 6 kW. By combining 0.5 kW, 1 kW and 1.5 kW load units, it achieves fine‑tuned loading in 0.5 kW increments.


    The unit is equipped with four heavy‑duty DC blowers and adopts a side‑airflow design. Together with fin‑type stainless‑steel electric heating tubes, nickel‑chromium resistor cores, thermal‑protection emergency cut‑off and MCB protection, it delivers stable, flexible and safe load‑test support for generators, UPS units, power modules, inverters and other AC power‑supply devices.


    Boasting compact dimensions of 483 × 480 × 267 mm, a lightweight weight of approximately 25 kg and three portable carrying handles, the RM‑6 can be conveniently installed in standard equipment racks, laboratory test benches or on‑site test stations. It is well‑suited for product R&D, factory inspection, maintenance and engineering commissioning applications.

    IMG_6592 拷贝

    Key Features and Advantages

    RATA RM-6 6kW Rack Mounted Load Bank For Data Center 7
    Compact Rack‑Mount Design
    Compact rack‑mount design to save installation space
    调节
    6kW Load Capacity
    6kW load capacity to cover low‑power test requirements
    冷却
    0.5kW Fine Load Adjustment
    Fine loading in 0.5 kW increments for more flexible test adjustment
    IMG_6589 拷贝 2
    Dual‑Channel Independent Load
    Dual‑channel independent load structure, facilitating per‑channel testing
    RATA RM-6 6kW Rack Mounted Load Bank For Data Center 11
    Forced‑Air Cooling
    Forced air cooling to maintain continuous heat dissipation in the load area
    RATA RM-6 6kW Rack Mounted Load Bank For Data Center 12
    Industrial‑Grade Resistors
    Industrial‑grade resistor elements, suitable for continuous‑load operation
    IMG_6594 拷贝
    Multi‑Protection & Quick Deployment
    Multiple protections to enhance operational safety; Complete connectors and matching cables for rapid deployment
    IMG_6592 拷贝
    Easy Transport & Installation
    Easy for transportation and on‑site installation
    IMG_6591 拷贝
    Space‑Saving
    Saves test floor space

    Product DRAWINGS

    1 (126)
    1 (126)
    2 (102)
    2 (102)
    3 (72)
    3 (72)

    Product Specifications

    Electrical parameters
    Rated Power 6 kW
    Power Source Single source
    Test Voltage 230 Vac   1 phase *2
    Frequency 50 Hz
    Total Steps 6  Steps
    Phase A (AC 1) 0.5+1+1.5 kW (3 kW)  
    Phase B (AC 2) 0.5+1+1.5 kW (3 kW)  
    Enclosure structure
    Enclosure 6U Rack Mount
    Dimensions 483 × 480× 267 mm
    Weight 25 kg
    Colour RAL 7046 (Telegrey)
    Quantity of fans 4
    Air Volume(CFM/Fan) 235 CFM
    Size of fan 120mm dia. 0.6A
    Connection IEC 60320 C20 × 2
    Cables 2 * 3core C19/20 terminated × 3 m
    Portability 3 Handles
    IP grade of complete enclosure 23
    Load bank control
    Temperature -20 °C to +50°C
    Latitude ≦2000 m.a.s.l
    Local control Circuit breakers
    Protections
    Thermal emergency cut-out
    MCB

    Key details

    01 (5)
    01 (5)
    02 (5)
    02 (5)
    04
    04
    03 (2)
    03 (2)

    FAQ

    1
    What type of load bank is the RM‑6?
    The RM‑6 is a 6 kW rack‑mount resistive load bank, mainly used for load‑performance testing of low‑power AC power‑supply equipment. It converts electrical energy into heat via resistor elements and exhausts the heat through fans to simulate real‑world electrical loads.
    2
    What is the maximum load power of the RM‑6?
    The total rated power of the RM‑6 is 6 kW. The unit has two channels, AC1 and AC2, with a maximum load power of 3 kW per channel, adding up to 6 kW for both channels.
    3
    What are the input voltage and frequency of the RM‑6?
    The rated test voltage is dual‑channel single‑phase AC230 V with a rated frequency of 50 Hz. Before connection, verify that the output voltage, frequency, phase conductor, neutral conductor, protective earth and power capacity of the power‑under‑test comply with the product technical specifications.
    4
    What is the minimum loading step of the RM‑6?
    The minimum loading step is 0.5 kW. Each channel consists of three load segments: 0.5 kW, 1 kW and 1.5 kW, which can be combined for segmented loading via circuit breakers. It can serve as a partial‑load or auxiliary test device and shall not replace a full‑scale load system matched to the rated power of the generator‑under‑test.
    5
    What cooling method does the RM‑6 adopt?
    The unit uses forced‑air cooling and is equipped with four 120 mm fans, each delivering approximately 235 CFM airflow. The fans feature a redundant‑airflow design to continuously reduce the temperature of resistor elements and internal load zones.
    6
    Why does the RM‑6 adopt a side‑airflow design?
    Side‑inlet and side‑airflow design improves layout flexibility and facilitates integration with cabinets, racks or test platforms. During installation, air‑intake and exhaust paths must remain unobstructed, and adequate ventilation clearance shall be reserved according to on‑site heat‑dissipation conditions.
    7
    How does the unit prevent overheating?
    Overheat protection is realized by forced‑air cooling and thermal‑protection emergency cut‑off. Fans continuously cool the load area. When temperature reaches the protection threshold, the thermal‑protection device cuts off the load circuit. The actual trip temperature and reset mode shall be subject to the final electrical documentation and factory settings.
    8
    Can the RM‑6 be installed in a standard cabinet?
    Designed as a 6U Rack‑Mount unit, it is intended for integration with standard cabinets, racks or test benches. Prior to physical installation, confirm the cabinet's usable internal height, depth, load‑bearing capacity, mounting method, air‑inlet / exhaust clearance and cable bending radius.
    9
    What connectors and cables are supplied with the unit?
    The unit is fitted with two IEC 60320 C20 connectors, supplied together with two pieces of 3‑meter‑long 3‑core C19‑to‑C20 cables with conductor size 3 × 2.5 mm². Before hard‑wiring, verify plug‑socket model, current rating, cable cross‑section and protective‑earth connection.
    10
    What basic safety requirements apply when operating the RM‑6?
    Before operation, confirm correct power‑supply voltage, frequency, phase connections and protective‑earthing; inspect integrity of cables and connectors; ensure fan intake and exhaust zones are unobstructed. Do not touch high‑temperature components or block ventilation openings during operation. In case of abnormal temperature rise, strange odors, fan failure, protection tripping or electrical anomalies, stop loading immediately and perform inspection in accordance with on‑site safety procedures.
    11
    Typical product delivery time?
    6 weeks.
    12
    Warranty service?
    2 years.
    13
    Do you provide installation and testing support?
    Yes, Rata provides on-site testing services, including equipment installation, configuration, and data logging.
    14
    How many countries have you exported to?
    We export to over 80 countries worldwide.
    15
    Why choose us?
    We have ISO、CE certification and are Authorized factories for Siemens and Schneider Electric brands.
    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    Customer service
    detect