loading
Best Rata Load Bank Company-4 1
Best Rata Load Bank Company-4 2
Best Rata Load Bank Company-4 3
Best Rata Load Bank Company-4 4
Best Rata Load Bank Company-4 5
Best Rata Load Bank Company-4 1
Best Rata Load Bank Company-4 2
Best Rata Load Bank Company-4 3
Best Rata Load Bank Company-4 4
Best Rata Load Bank Company-4 5

Best Rata Load Bank Company-4

Inquiry

Product Overview

- The Rata load bank is an industrial-grade, air-cooled resistive load bank available in a 1MW / 1000 kW model (RT1000kWLB) for 3-phase AC systems.

- Designed for outdoor deployment (canopy) with continuous-duty operation and broad environmental tolerances (–20 °C to 50 °C, up to 2,500 m altitude).

- Built for accurate, repeatable electrical testing of generators, UPS and other power systems.

Best Rata Load Bank Company-4 6
Best Rata Load Bank Company-4 7

Product Features

- Electrical: 3-phase 4-wire, AC380/400/415 V (custom voltages available), 50/60 Hz, loading accuracy ≤ 3%, 3-phase unbalance ≤ 3%.

- Loading & control: 1 kW resolution load steps, multiple step sizes up to 100 kW, parallel expansion of multiple units, local panel and remote PC control (Modbus TCP supported).

- Construction & cooling: forced air cooling with axial fans (noise < 80 dB at 3 m), 8020 Ni‑Cr alloy finned resistors, IP54 enclosure (Q235 steel, powder coated).

- Measurement & analysis: real-time data acquisition, storage, automated/reporting, harmonic analysis (2nd–50th), voltage/current/frequency curves and energy accumulation.

- Protections & extras: overtemperature, low airflow, phase-sequence, short circuit, fan interlock, emergency stop; forklift holes for movement; OEM/ODM customization.

Product Value

- Delivers reliable, standardized commissioning and acceptance testing for generators, UPS and power systems, reducing operational risk and ensuring compliance with national, military, marine and telecom standards.

- Provides detailed test data, automated reports and harmonic analysis to support diagnostics, performance validation and regulatory documentation.

- Long expected service life (~20 years) and comprehensive after-sales support minimize lifecycle cost and downtime.

Best Rata Load Bank Company-4 8
Best Rata Load Bank Company-4 9

Product Advantages

- Certified quality and compliance: CE, ISO9001/14001/45001 and SGS; designed per relevant IEC/GB/GJB standards.

- High-quality components sourced from leading brands and proven over 11 years of cooperation for durability and serviceability.

- Strong support & service: 7×24 technical support, 12‑month warranty from commissioning, rapid response times and on‑site service within 24–72 hours when needed.

- Flexible supply: OEM/ODM options (custom design, logo, color), remote interfaces (RJ45/RS232/RS485/Modbus TCP) and modular parallel expansion.

- Practical site design: outdoor-capable canopy, forklift handling, robust protections, and continuous-duty cooling for long test durations.

Application Scenarios

- Generator set commissioning, load bank testing and acceptance (diesel, gas, synchronous machines).

- UPS, data center and standby-power verification and maintenance.

- Marine, military and telecom power system testing and certifications.

- Factory testing, R&D labs and service centers for power equipment.

- Grid emulation, harmonic analysis and stress testing during installation or routine preventive maintenance.

Best Rata Load Bank Company-4 10
Contact us
we welcome custom designs and ideas and is able to cater to the specific requirements. for more information, please visit the website or contact us directly with questions or inquiries.
no data
Customer service
detect