Product Overview
Certainly! Here is a summarized description of the "Container Load Bank Products Wholesale - Rata" based on the detailed introduction:
Product Features
**Product Overview**
Product Value
Rata’s Container Load Bank is a high-capacity, outdoor, resistive-reactive load testing unit built to ISO9001:2000 quality standards. It features a 50,000 kVA apparent power capacity at 400V with a power factor of 0.8, designed for simulating real-world electrical load conditions on generators, UPS systems, and power distribution networks. Housed within a containerized carbon steel enclosure with marine-grade painting, it supports rugged outdoor use.
Product Advantages
**Product Features**
Application Scenarios
- Combined resistive and reactive load configuration (PF 0.8)
- Air-cooled system with horizontal intake and vertical exhaust (12 fans, 27000 CMH total airflow)
- Load steps with fine resolution for active and reactive power
- Robust protection mechanisms: thermal cutoff, airflow monitoring, fan overload, emergency stop
- Customization options for voltage, power capacity, air cooling direction, and control sources
- Local/manual and remote/PLC/computer-based control options, with cloud monitoring available
- High ambient temperature rating (+60°C) and IP54 control chamber rating
**Product Value**
This product ensures reliable and accurate load simulation critical for validating and maintaining power generation and distribution systems. Its highly customizable design caters to diverse testing needs and customer specifications. The robust construction and safety features provide durable, reliable operation even in harsh outdoor environments, helping reduce downtime and improve system reliability.
**Product Advantages**
- Manufactured with strict quality control, involving over 40 quality checks before shipment
- Designed and built by an experienced, skillful technical team with advanced production lines
- Flexible load bank configurations supporting a wide power range (10kW to multiple MW)
- Comprehensive safety and protection systems to safeguard equipment and operators
- Ability to deliver turnkey solutions including onsite commissioning, testing services, and operator training
- ISO-certified quality management backs product consistency and trustworthiness
**Application Scenarios**
The Rata Container Load Bank is suited for testing and commissioning in:
- Power plants (generators and turbine testing)
- UPS and backup power systems
- Data centers and telecommunication facilities
- Industrial and commercial power distribution networks
- Maintenance testing for electrical infrastructure to ensure operational reliability under load
- Situations requiring portable, high-capacity load simulation in outdoor or rugged environments
Let me know if you need the summary adjusted or expanded!
|
Description |
|
|
Model No. |
X5000L |
|
Country of origin |
China |
|
Apparent power capacity |
5000 kVA |
|
Active power capacity(PF 1.0) |
4000 kW |
|
Rated testing voltage |
400 Vac |
|
Load step(Active power) |
100+200+200+500+1000*3KW |
|
Load resolution |
100kW |
|
Reactive power capacoty(PF0.8) |
3000 kVAR |
|
Load step (Reactive power) |
10+20+20+50+100+100+150*18 KVAR |
|
Load resolution(Reactive power) |
10kVar |
|
Frequency |
50Hz. |
|
Phases wires |
3ph 4w |
|
Voltage Tolerance (Short Term Operation) |
+5% |
|
Load Element Tolerance |
≤+2.5% |
|
Insulation Test |
600 Vac |
|
Load Connections |
Copper busbars |
|
Protection |
Thermal emergency cut out |
|
Air flow switch |
|
|
Fan overload protection |
|
|
Emergency stop |
|
|
Control voltage |
3ph 400VAC 50/60HZ. |
|
Airflow volume(Approx. CMM) |
2700 CM/H *8 |
|
Airflow direction |
Vertical upwards air forced cooling |
|
Fans Nos. |
12 pcs . (4kW each) |
|
Load switching contactor type |
3 pole AC contactors |
|
Rated maximum ambient temp. operation |
+60°C / +140°F |
|
Rated minimum ambient temp. operation |
-20°C / -4°F |
|
Altitude rating |
≤2000 [m.a.s.l] or customized |
|
Control chamber IP rating |
IP 54 outdoor |
|
Enclosure material |
Containerised carbon steel with marine grade painting. |
|
Portabality |
Standard ISO lifting points |
|
Enclosure dimentions |
|
|
Length(mm) |
9500 |
|
Width(mm) |
2438 |
|
Height(mm) |
2800 |
|
Weight of load bank |
20000 Maximum |