Product Overview

- Heavy-duty DC resistive load bank (example model: 1 MW / R1000kW / 400 V / 50 Hz) designed for static, fluctuation and transient (sudden load addition/unloading) testing of diesel generators and power sources.

- Complete system includes dry resistance elements, electrical control components and measurement & control system with local and centralized data storage.

- Real‑time acquisition, visualization, automated analysis and report generation; supports harmonic analysis (2nd–50th) and full electrical parameter measurement (voltage, current, frequency, power, harmonics, recovery times).

- Built to meet national, ship, military and telecommunication test standards; scalable and customizable in power, voltage and form factor.

Dc Resistive Load Bank Factory​ Rata Load Bank Wholesale - Rata-1 5
Dc Resistive Load Bank Factory​ Rata Load Bank Wholesale - Rata-1 6

Product Features

- Test modes: steady-state, fluctuation, transient/sudden load addition and unloading, and generator setting tests.

- Data capabilities: real-time display, local + centralized storage, automated charts/reports, manual charting, harmonic content analysis, energy accumulation.

- Control & accuracy: selectable local manual, local automatic or remote automatic control; loading accuracy ≤ 3%; minimum step 1 kW; three-phase unbalance ≤ 3%.

- Protection & reliability: short-circuit, overcurrent, over-temperature and fan-fault protections; continuous duty; forced air cooling; insulation class F.

- Expandability & transport: parallel expansion of multiple load containers; lifting holes and rollers for easier transport and installation.

- Measurement accuracy: display accuracy 0.5, sampling accuracy 0.2.

Product Value

- Provides comprehensive, standards-compliant verification of generators and power systems — including transient response and harmonic performance — enabling confident commissioning and acceptance testing.

- Rich, customizable reports and automated analysis speed troubleshooting, acceptance processes and regulatory compliance.

- Scalable and configurable to customer needs, reducing the need for multiple test systems and lowering capital and operational costs.

- Robust protections and continuous duty capability maximize safety and uptime during testing.

- Strong installation, training and lifetime technical support reduce user risk and accelerate operator competency.

Dc Resistive Load Bank Factory​ Rata Load Bank Wholesale - Rata-1 7
Dc Resistive Load Bank Factory​ Rata Load Bank Wholesale - Rata-1 8

Product Advantages

- Broad test coverage (steady, transient, harmonic) and high measurement fidelity make it suitable for demanding industrial, marine, military and telecom applications.

- Deep harmonic analysis (2nd–50th) and full electrical parameter capture distinguish it from simpler load banks.

- Flexible control options (manual/auto/remote) and fine resolution (1 kW step) allow precise, repeatable testing.

- Comprehensive after-sales: 3-year warranty from acceptance, 2-hour response guarantee, onsite support within 7 working days, lifetime paid maintenance and spare parts supply.

- Backed by patents, software copyrights and recognition as a national high‑tech enterprise — indicating mature R&D and quality processes.

Application Scenarios

- Diesel generator factory acceptance testing (FAT) and site commissioning.

- Shipboard and marine generator test programs to meet ship standards.

- Military, telecom and utility compliance testing and routine maintenance verification.

- Power plant, UPS and backup system commissioning, performance validation and transient response checks.

- Research, training labs and service centers performing harmonic, load-profile and endurance testing.

Dc Resistive Load Bank Factory​ Rata Load Bank Wholesale - Rata-1 9
Contact us
we welcome custom designs and ideas and is able to cater to the specific requirements. for more information, please visit the website or contact us directly with questions or inquiries.