Product Overview
- Rata 2000 kW (2 MW) resistive dummy load bank in a containerized IP54 enclosure, designed for outdoor generator load testing (rated voltage 6000 VAC, 3-phase, 3-wire).
- Compact skid/container size 4500 × 2530 × 2600 mm, weight ~6,500 kg, hoisting points for transport and installation.
- Control by local panel or remote PC (Siemens PLC, Modbus TCP over RJ45; RS485/RS232 optional). Digital meters show voltage, current, power, power factor and frequency.
Product Features
- Resistive-only 2000 kW capacity with modular load steps: 50+50+100+100+200+500+500+500 kW.
- High-quality 80/20 Ni–Cr finned resistors and tin-plated copper busbars.
- Forced-air cooling: horizontal intake (protected by cover/mesh) and vertical hot-air outlet with ducting.
- Comprehensive protection and alarms: high temperature, low air flow, fan interlock, phase sequence, over-voltage/current, short circuit, smoke detection, temp & humidity control, access control and emergency stop.
- Flexible control and communications, load data logging/printing, multi-language operation software.
Product Value
- Provides accurate, repeatable, full-load testing and commissioning for large generators to verify performance, stability and protection settings without stressing customer loads.
- Reduces downtime and risk by enabling safe, instrumented load application and diagnostics (measurable voltage, current, power factor, frequency).
- Speeds commissioning and acceptance testing (FAT available) and supports operator training to ensure correct on-site use.
- OEM/ODM customization (design, logo, color) and global logistics/after-sales support lower integration and lifecycle costs.
Product Advantages
- Robust, weather-resistant container design (IP54) built with precision manufacturing and rigorous testing for high tolerance and reliability.
- Strong global support network: 27-city reach, 50 delivery centers, 7×24 after-sales service and fast delivery capability.
- Compatibility and credibility via partnerships with major electrical brands; offers factory acceptance testing and free on-site training during visits.
- Flexible communications and control options for integration into customer systems; customizable to specific client requirements.
Application Scenarios
- Primary: oil-field and large industrial generator load testing and commissioning (explicitly designed for oil field generator load tests).
- Power plant commissioning and maintenance, rental fleet verification, generator manufacturers’ production testing and FAT.
- Critical facility periodic testing (data centers, hospitals, telecom), contractor site acceptance tests, and emergency/standby generator validation.