Product Overview
- Rata Load Bank (hot-selling) — a high-capacity resistive‑inductive load bank designed primarily for ship generator load testing.
- Single model example: 5 units rated 5000 kVA / 4000 kW / 3000 kvar, power factor 0.8, for 3-phase 4‑wire systems at 400 V / 690 VAC.
- Built for heavy-duty, on‑site generator verification with horizontal air discharge cooling and modular, easy-install/remove resistor elements.
Product Features
- High-rated capacity: 5000 kVA / 4000 kW / 3000 kvar, PF 0.8.
- Voltage and connections: 400V/690VAC, 3‑phase 4‑wire, tin‑plated copper busbar terminations. Control supply 380 VAC.
- Construction: Ni‑Cr alloy resistors, 3‑phase inductors, horizontal axial‑fan air discharge cooling, IP54 protection.
- Control options: local panel switching control and remote PC control using supplied Rata operation software.
- Physical: robust dimensions (6000 × 2438 × 2900 mm), weight ~18,000 kg; designed for ease of installation and disassembly of resistor modules.
- Quality assurance: internal QC, strict pre‑delivery inspection and production capacity for large orders.
Product Value
- Provides accurate, repeatable full‑load simulation for generator and shipboard power systems to validate performance, reliability and safety.
- Reduces commissioning and maintenance risk by enabling controlled, measurable load testing.
- Saves time in troubleshooting and acceptance testing by offering both local and remote control.
- Supports large-scale and repeat testing needs due to high capacity and production/stock capability.
Product Advantages
- Very high power rating suitable for large generator and ship applications.
- Durable components (Ni‑Cr resistors, tin‑plated copper bars, IP54 enclosure) for reliable operation in industrial/marine environments.
- Flexible control: on‑site panel or remote PC operation with supplier software.
- Designed for maintainability: easy install/disassemble resistor modules and rugged cooling layout.
- Manufacturer reliability: in‑house quality control, strict inspections, export experience and customer service orientation.
Application Scenarios
- Ship and marine generator load testing and commissioning (primary intended use).
- Industrial and utility generator acceptance tests and maintenance.
- Power plant commissioning and performance verification.
- Backup power/UPS system testing for data centers and critical facilities.
- OEM and factory testing where large, configurable resistive/inductive loads are required.