loading
Hot Selling Rata Load Bank Company-2 1
Hot Selling Rata Load Bank Company-2 2
Hot Selling Rata Load Bank Company-2 3
Hot Selling Rata Load Bank Company-2 4
Hot Selling Rata Load Bank Company-2 5
Hot Selling Rata Load Bank Company-2 1
Hot Selling Rata Load Bank Company-2 2
Hot Selling Rata Load Bank Company-2 3
Hot Selling Rata Load Bank Company-2 4
Hot Selling Rata Load Bank Company-2 5

Hot Selling Rata Load Bank Company-2

Warranty time:
3 years
ISO Certification:
ISO9001/ISO14001
Brand:
RATA
ODM & OEM:
Available
Certification:
CE 60204 Standard
Inquiry
Send your inquiry

Product Overview

1) Product overview

Hot Selling Rata Load Bank Company-2 6
Hot Selling Rata Load Bank Company-2 7

Product Features

- Container-type AC resistive load bank designed for 440 VAC / 380 VAC power systems.

Product Value

- Dual rating: 2680 kW at 440 VAC and 2000 kW at 380 VAC. IP54 enclosure, dimensions 4500 × 2530 × 2600 mm, weight ~7,500 kg.

Hot Selling Rata Load Bank Company-2 8
Hot Selling Rata Load Bank Company-2 9

Product Advantages

- Purpose-built for high-capacity generator and power-source testing, commissioning and maintenance.

Application Scenarios

2) Product features

- Containerized design with horizontal air intake and vertical air outlet via ducting; water- and snow-proof, intake protected by cover and steel mesh. Lift lugs and customizable enclosure color.

- Control: local panel switching and remote PC control; supports generator tester, PLC systems, RJ45 (Cat6) connection, curves/charts/tables, data saving and printing.

- Load steps: 10 kW + 20 kW + 30 kW + 40 kW + 100 kW ×4 + 500 kW ×3 (flexible staged loading).

- Cooling: forced-air axial fans, noise < 80 dB at 3 m. Resistive elements: 80/20 Ni‑Cr alloy finned resistors.

- Protections: short circuit, overcurrent, overtemperature, low airflow, fan fault, emergency stop, access control and smoke alarm.

3) Product value

- Enables full-capacity, controlled load testing of large generators and power systems to verify performance, heat rejection and electrical stability under real load conditions.

- Reduces commissioning time and risk by providing reliable, repeatable load steps and comprehensive data logging/printing.

- Weatherproof container and integrated protection systems allow safe on-site use in varied environments, improving uptime and operational confidence.

4) Product advantages

- Very high power capacity in a single portable container (up to 2680 kW), suitable for utility-scale and industrial generator testing.

- Flexible control options (local/remote, PLC, PC) and fine-grained load steps for precise testing profiles.

- Rugged construction and IP54 weather protection for outdoor deployment; anti-foreign-object intake protection and lift lugs for easy movement.

- Robust safety and monitoring features plus quieter operation (≤80 dB at 3 m) compared with many open-frame solutions.

- Manufactured to international quality standards with customization and sustainable design practices.

5) Application scenarios

- Full-load and partial-load testing of diesel/gas generator sets and power plants.

- Commissioning and acceptance testing for new installations, factory or site acceptance tests.

- Routine maintenance, load bank exercise to prevent wet-stacking and ensure generator health.

- Power system verification for industrial facilities, data centers, hospitals, and large commercial sites.

- Temporary load provision or simulated loads for research, training, and development of control systems.

Hot Selling Rata Load Bank Company-2 10
Data Sheet

Product name

2680kW/2000kW load bank

Rated power capacity

R2680kW:440V/2000kW:380V
Rated voltage440VAC/380VAC,3 phase 4 wire,connected with tin plated copper bar
Control voltage380VAC,3 phase 4 wire,connected with terminal
Communication interfaceRJ45

Load steps

10kW+20kW+30kW+40kW+100kW+100kW+100kW+100kW+500kW+500kW+500kW

Resistor

8020 Ni-Cr alloy finned resistors

Load control

Local panel switching control and remote PC control,generator tester,PLC system,RJ45 interface,super 6 category net cable,curve,chart,table,support load data save and printing

Loading accuracy

≤ 3%

Three phase balance

Unbalance degree ≤ 3%

Minimum step

10kW

Working mode

Continuous work

Load protection

Short circuit,overcurrent,high temperature,low air volume,fan fault protection,emergency stop,access control.smoke alarm

Cooling 

Forced air cooling.Horizontal air intake and vertical air outlet with air duct.Axial fans,noise less than 80dB in 3 meters.

Insulation class

F

Measurement accuracy

The display accuracy is 0.5,the sampling accuracy is 0.2

Electrical parameter display

Three phase voltage, three-phase current, frequency, power, power factor,etc

Load expansion

Parallel expansion of multiple loads

Standard

Meet international standard, ship standard, military standard and telecommunication standard

Transport

Lift lugs on the top of the load bank

Color

Customized

Dimensions4500mm*2530mm*2600mm (L*W*H)
Weight7500Kg

Ambient temperature

-20℃ to 50℃

Humidity

Up to 100%

Altitude

Up to 2500m

Atmospheric pressure

86 to 106kPa


Design

load bank design

Contact us
we welcome custom designs and ideas and is able to cater to the specific requirements. for more information, please visit the website or contact us directly with questions or inquiries.
no data
Customer service
detect