Product Overview
- 1MW / 1000 kW three‑phase AC resistive load bank (model RT1000kWLB), outdoor canopy design for continuous duty.
- Rated for common voltages (AC 380V / 400V / 415V or customer‑specified), 50/60 Hz, 3‑phase 4‑wire connection.
- Built for full generator and UPS testing with local panel and remote PC control (Modbus TCP), on‑board data storage and centralized display.
Product Features
- Precise, stepwise loading: 1 kW resolution with multiple step groups (1kW, 2kW, 2kW, 5kW, 10kW, 10kW, 20kW, 50kW, 9×100kW).
- Measurement & analysis: real‑time acquisition, display and storage of voltage, current, power, PF, frequency, harmonics (2nd–50th) and energy accumulation; automatic charting and report generation.
- Performance & protection: loading accuracy ≤3%, phase unbalance ≤3%, IP54 enclosure, protections for high temp, low airflow, phase sequence, short circuit, fan interlock and emergency stop.
- Robust construction: 8020 Ni‑Cr finned resistors, forced axial air cooling (≤80 dB at 3 m), Q235 powder‑coated steel enclosure, forklift holes for mobility.
- Control & expandability: local/manual switching plus remote control (Modbus TCP, PLC, operation software), parallel expansion of multiple load banks.
Product Value
- Ensures comprehensive, repeatable, standards‑compliant testing of gensets and UPS systems (steady‑state, fluctuation, transient/sudden load add/remove), enabling verification of voltage/current/frequency ranges and recovery behavior.
- Reduces commissioning and maintenance risk by providing detailed test reports and visual analysis, improving reliability of backup power systems.
- Saves time and cost through portable, outdoor‑ready equipment that supports on‑site testing across industries; OEM/ODM options enable tailored solutions.
- Delivers long service life (design life ~20 years) with professional after‑sales support to protect customer investment.
Product Advantages
- Certified and quality‑controlled: CE, ISO9001/14001/45001, SGS; built with first‑tier brand components.
- Strong data capability: local + centralized storage, automated analysis, harmonics and energy measurement.
- Responsive service: 7×24 after‑sales support, 12‑month warranty from commissioning, fast technical response (2–10 hours remote; 24–72 hours on‑site if needed) and lifelong paid maintenance options.
- Flexible deployment: outdoor canopy, wide ambient range (–20°C to 50°C), altitude up to 2500 m, and multiple safety/operational protections.
- Customizable: configurable voltages, colors, logos, and control interfaces; compatible with standard protocols and common industrial partners (ABB, Schneider, Siemens, etc.).
Application Scenarios
- Generator commissioning, performance and load bank testing for diesel and gas gensets (power plants, rental fleets).
- UPS testing and validation for data centers, hospitals and industrial control rooms.
- Telecom and broadcast site generator acceptance and maintenance.
- Marine, military and railway equipment testing where ship/military/telecom standards compliance is required.
- Factory acceptance tests, periodic preventative maintenance, emergency system verification and lab/engineering test facilities.