Product Overview
Certainly! Here is a summarized description of the "Rata AC Inductive Load Banks for Sale" based on the detailed introduction:
Product Features
**Product Overview**
Product Value
Rata AC Inductive Load Banks are robust, high-performance electrical load testing devices specifically designed for resistive and inductive load simulation. They are container-type, air-cooled units capable of long-term continuous operation under extreme environmental conditions. The load banks are suitable for testing generators, power plants, industrial electronics, and other power systems.
Product Advantages
**Product Features**
Application Scenarios
- Combination of resistive and inductive load elements with fine resolution steps for precise loading
- Air cooling with low noise axial fans and powder-coated steel enclosure
- Digital metering of voltage, current, power, power factor, and frequency
- Flexible operation modes: local panel control and remote PC operation via Modbus TCP
- Parallelable load expansion and strict compliance with international, ship, military, and telecom standards
- Wide operational temperature (-20°C to 50°C), humidity tolerance, and altitude capability
**Product Value**
These load banks provide reliable and accurate simulation of electrical loads critical for preventive maintenance, commissioning, and performance verification of power generation and electronic equipment. They ensure system stability, prevent equipment issues like wet stacking in diesel generators, and improve confidence in power system reliability. Long product life and flexible adaptability reduce downtime and operational risk.
**Product Advantages**
- Over 11 years of manufacturing expertise and proven global export record
- High-quality components from top-tier brands (e.g., ABB, Schneider, Siemens) ensuring durability and precision
- Comprehensive after-sales support with 24/7 technical assistance, onsite service within 24–72 hours, and lifelong maintenance options
- Certified quality assurance (CE, ISO9001, ISO14001, ISO45001, SGS) and independent export rights
- Custom OEM/ODM services allowing personalized design, branding, and technical configurations
**Application Scenarios**
Rata’s AC Inductive Load Banks are ideal for a broad range of sectors including:
- Ship and offshore generator testing
- Power plants and electricity stations
- Aviation and military power test platforms
- Oil, chemical, drilling, and mining industries
- Self-owned power plants and data centers
- Manufacturing, renewable energy sites, and electrical equipment rental services
They serve as essential tools for verifying generator capacity, power factor correction, frequency and voltage stability, and overall system integration under simulated load conditions.
|
Product name |
2500kW/2000kvar Resistive Inductive Load Bank; |
| Model number | RT3125kVALB; |
| Design | Container type design |
|
Rated power |
AC 380V,400V,415V,440V,690V,customized. 3 phase 4 wire. Connected with tin plated copper bar; |
| Control power |
AC380V,3 phase 4 wire,connected with quick coonector/terminal; |
| Frequency | 50Hz/60Hz; |
| Loading accuracy | ≤ 3%; |
| 3 phase balance | Unbalance degree ≤ 3%; |
| Duty cycle | Continuous work |
| Insulation | F |
|
Operation mode |
1)Local panel switching operation 2)Remote PC operation(Mod bus TCP communication protocol,PLC system,operation software,support load data save and printing); |
|
Resistive load steps |
1kW resolution;1kW+2kW+2kW+5kW+10kW+10kW+20kW+50kW+100kW+100kW+200kW×11; |
|
Resistor |
8020 Ni-Cr alloy finned resistor; |
| Inductive load steps | 1kvar resolution;1kvar+2kvar+2kvar+5kvar+10kvar+10kvar+20kvar+50kvar+100kvar+200kW×9; |
| Inductor | 3 phase inductor; |
|
Cooling system |
Forced air cooling;horizontal air intake and vertical outlet;Axial fan,noise less than 80dB at 3m distance; |
| Enclosure | Q235 steel,powder coated. |
|
Protection |
High temperature,low air volume,phase sequence,short circuit,fan interlock,emergency stop; |
|
Digital meter |
Voltage,current,power,power factor and frequency; |
|
Load expansion |
Parallel expansion of multiple loads; |
|
Standard |
Meet international standard,ship standard,military standard and telecommunication standard; |
|
Movement |
Lift lugs on the top of the load bank; |
|
Color |
RAL 7035(industrial grey); |
| Dimensions | 6000mm*2530mm*2900mm (L*W*H) |
| Weight | 18000Kg |
|
Ambient temperature |
-20℃ to 50℃ |
|
Humidity |
Up to 100% |
|
Altitude |
Up to 2500m |
|
Atmospheric pressure |
86 to 106kPa |
Design drawing:
Details:
Device layout
Wiring busbar
Manual control panel