loading
Rata Ac Load Bank Manufacturer for Sale-1 1
Rata Ac Load Bank Manufacturer for Sale-1 2
Rata Ac Load Bank Manufacturer for Sale-1 3
Rata Ac Load Bank Manufacturer for Sale-1 4
Rata Ac Load Bank Manufacturer for Sale-1 1
Rata Ac Load Bank Manufacturer for Sale-1 2
Rata Ac Load Bank Manufacturer for Sale-1 3
Rata Ac Load Bank Manufacturer for Sale-1 4

Rata Ac Load Bank Manufacturer for Sale-1

Delivery time:
6 weeks
Brand:
RATA
Factory Price:
Negotiate
Port:
Shanghai and Guangzhou are both available
Certification:
CE 60204 Standard
Inquiry

Product Overview

1) Product overview

Rata Ac Load Bank Manufacturer for Sale-1 5
Rata Ac Load Bank Manufacturer for Sale-1 6

Product Features

- Rata’s R2500kW / L2000kvar three-phase air-cooled resistive–inductive load bank (model RT3125kVALB) is a container-style power load test device designed for radar load test platforms and general power system testing. It supports 3-phase 4-wire systems at selectable nominal voltages (380V/400V/415V/440V/690V or custom), 50/60 Hz, and continuous duty operation. The assembly includes resistive banks, inductive banks and an integrated control system.

Product Value

2) Product features

Rata Ac Load Bank Manufacturer for Sale-1 7
Rata Ac Load Bank Manufacturer for Sale-1 8

Product Advantages

- Combined resistive and reactive (inductive) loading with fine step resolution (1 kW / 1 kvar resolution and predefined step groups up to 200 kW/200 kvar).

Application Scenarios

- Local panel and remote control via PLC and Modbus TCP with operation software, data saving and printing.

- Forced air cooling (axial fans, horizontal intake/vertical outlet) with noise < 80 dB at 3 m.

- Digital metering of voltage, current, power, power factor and frequency; multiple protective interlocks (high temperature, low airflow, phase sequence, short circuit, fan interlock, emergency stop).

- Parallel expansion capability to combine multiple units.

3) Product value

- Provides accurate, repeatable and visible load capability for commissioning, routine testing and long-duration verification of generators, power systems, radar platforms and related equipment.

- Reduces test preparation time and simplifies operation (local or automated remote control), increasing productivity and lowering operational risk.

- Built to meet ship, military and telecommunication standards, making it suitable for critical and regulated environments.

4) Product advantages

- High loading accuracy (≤ 3%) and three-phase balance/unbalance control (≤ 3%) for reliable test results.

- Robust industrial construction (Q235 steel enclosure, powder coated), standardized dimensions for container deployment and lift lugs for movement.

- Modular step design and parallel expansion permit precise loading profiles and scalable capacity.

- Comprehensive protection features and continuous-duty design support long-term, unattended operation.

- Manufactured with experienced processes and quality inspection for durability and stable performance.

5) Application scenarios

- Radar platform and military system load testing and verification.

- Generator set and prime mover commissioning and routine load testing.

- Telecom and shipboard power system testing (meets relevant standards).

- Data center, UPS, inverter and industrial plant load simulation and acceptance testing.

- Factory commissioning, maintenance, and any scenario requiring controlled resistive/reactive load application and accurate power measurements.

Rata Ac Load Bank Manufacturer for Sale-1 9
Data Sheet


Product name

2500kW/2000kvar Resistive Inductive Load Bank;
Model numberRT3125kVALB;
DesignContainer type design

Rated power

AC 380V,400V,415V,440V,690V,customized. 3 phase 4 wire. Connected with tin plated copper bar;

Control power

AC380V,3 phase 4 wire,connected with quick coonector/terminal;

Frequency50Hz/60Hz;
Loading accuracy≤ 3%;
3 phase balanceUnbalance degree ≤ 3%;
Duty cycleContinuous work
InsulationF

Operation mode

1)Local panel switching operation

2)Remote PC operation(Mod bus TCP communication protocol,PLC system,operation software,support load data save and printing);

Resistive load steps

1kW resolution;1kW+2kW+2kW+5kW+10kW+10kW+20kW+50kW+100kW+100kW+200kW×11;

Resistor

8020 Ni-Cr alloy finned resistor;

Inductive load steps1kvar resolution;1kvar+2kvar+2kvar+5kvar+10kvar+10kvar+20kvar+50kvar+100kvar+200kW×9;
Inductor3 phase inductor;

Cooling system

Forced air cooling;horizontal air intake and vertical outlet;Axial fan,noise less than 80dB at 3m distance;

EnclosureQ235 steel,powder coated.

Protection

High temperature,low air volume,phase sequence,short circuit,fan interlock,emergency stop;

Digital meter

Voltage,current,power,power factor and frequency;

Load expansion

Parallel expansion of multiple loads;

Standard

Meet international standard,ship standard,military standard and telecommunication standard;

Movement

Lift lugs on the top of the load bank;

Color

RAL 7035(industrial grey);

Dimensions6000mm*2530mm*2900mm (L*W*H)
Weight18000Kg

Ambient temperature

-20℃ to 50℃

Humidity

Up to 100%

Altitude

Up to 2500m

Atmospheric pressure

86 to 106kPa


Design drawing:

2500kW2900


Details:

load bank_0948

Device layout


load bank

Wiring busbar


Rata Ac Load Bank Manufacturer for Sale-1 13

Manual control panel


Contact us
we welcome custom designs and ideas and is able to cater to the specific requirements. for more information, please visit the website or contact us directly with questions or inquiries.
no data
Customer service
detect