loading
Rata Load Bank by Rata-2 1
Rata Load Bank by Rata-2 2
Rata Load Bank by Rata-2 3
Rata Load Bank by Rata-2 4
Rata Load Bank by Rata-2 5
Rata Load Bank by Rata-2 6
Rata Load Bank by Rata-2 7
Rata Load Bank by Rata-2 1
Rata Load Bank by Rata-2 2
Rata Load Bank by Rata-2 3
Rata Load Bank by Rata-2 4
Rata Load Bank by Rata-2 5
Rata Load Bank by Rata-2 6
Rata Load Bank by Rata-2 7

Rata Load Bank by Rata-2

Inquiry
Send your inquiry

Product Overview

Certainly! Here is a summarized description of the “Rata Load Bank by Rata” based on the detailed introduction provided:

Rata Load Bank by Rata-2 8
Rata Load Bank by Rata-2 9

Product Features

**Product Overview**

Product Value

The Rata Load Bank is a high-capacity resistive inductive load bank designed primarily for testing and measuring the rated power factor and performance of diesel generator sets, especially in shipyards. The flagship model features 500kW active power and 375kvar reactive power, suitable for 3-phase AC systems at various voltages (380V to 690V). It supports continuous operation with precise load control and digital monitoring, ensuring reliable performance testing under different load conditions.

Rata Load Bank by Rata-2 10
Rata Load Bank by Rata-2 11

Product Advantages

**Product Features**

Application Scenarios

- Accurate loading steps with fine resolution for both resistive (1kW increments) and inductive loads (1kvar increments).

- Forced air cooling system with low noise output (less than 80dB at 3 meters).

- Dual operation modes: local panel control and remote PC operation with Modbus TCP protocol.

- Robust design meeting multiple international, military, and marine standards.

- Digital meters for voltage, current, power, power factor, and frequency monitoring.

- Parallel expansion capability for larger testing requirements.

- Heavy-duty enclosure with corrosion-resistant powder coating and various built-in protections (temperature, short circuit, phase sequence, fan interlock).

**Product Value**

- Ensures reliable and accurate testing of generator sets to verify efficiency and power factor under load.

- Extends generator lifespan by preventing overload or insufficient testing.

- Supports custom configurations (OEM/ODM) with tailored design, logo, and color options.

- Provides long-term operational stability with high-quality internal components from leading industry brands.

- Comprehensive after-sales support with quick response, free warranty maintenance, and lifelong paid technical services.

**Product Advantages**

- Compliance with multiple quality and safety certifications including CE, ISO9001, ISO14001, ISO45001, and SGS.

- Supports continuous duty cycle with forced air cooling for heavy, prolonged use.

- Versatile control interfaces (RJ45, RS232, RS485) compatible with common industrial protocols.

- Modular and scalable design allowing parallel connections for larger loads.

- Professional technical support ensuring rapid troubleshooting, updates, and customer training.

- Durable mechanical construction with lift lugs and forklift holes for easy transportation and installation.

**Application Scenarios**

- Shipyard generator load testing and marine turbine generator inspection.

- Testing shore power supply systems for ships and aviation power performance verification.

- Inspection and functional testing of uninterruptible power supplies (UPS).

- Verification of emergency power supply vehicles and mobile power stations.

- Military, telecommunications, and industrial power generator maintenance and quality assurance.

This summary reflects the key points about Rata Load Bank’s capabilities, technical strengths, benefits, quality assurance, and practical uses.

Rata Load Bank by Rata-2 12
Products Description

 

Product name

500kW/375kvar Resistive Inductive Load Bank;
Model number RT625kVALB;
Design Indoor design

Rated power

AC 380V,400V,415V,440V,690V,customized. 3 phase 4 wire. Connected with tin plated copper bar;

Control power

AC380V,3 phase 4 wire,connected with quick coonector/terminal;

Frequency 50Hz/60Hz;
Loading accuracy ≤ 3%;
3 phase balance Unbalance degree ≤ 3%;
Duty cycle Continuous work
Insulation F

Operation mode

1)Local panel switching operation

2)Remote PC operation(Mod bus TCP communication protocol,PLC system,operation software,support load data save and printing);

Resistive load steps

1kW resolution;1kW+2kW+2kW+5kW+10kW+10kW+20kW+50kW+100kW+100kW+100kW+100kW;

Resistor

8020 Ni-Cr alloy finned resistor;

Inductive load steps 1kvar resolution;1kvar+2kvar+2kvar+5kvar+5kvar+10kvar+10kvar+20kvar+20kvar+50kvar+50kvar+100kvar+100kvar;
Inductor 3 phase inductor;

Cooling system

Forced air cooling;horizontal air intake and vertical outlet;Axial fan,noise less than 80dB at 3m distance;

Enclosure Q235 steel,powder coated.

Protection

High temperature,low air volume,phase sequence,short circuit,fan interlock,emergency stop;

Digital meter

Voltage,current,power,power factor and frequency;

Load expansion

Parallel expansion of multiple loads;

Standard

Meet international standard,ship standard,military standard and telecommunication standard;

Movement

Lift lugs and forklift holes

Color

RAL 7035(industrial grey);

Dimensions 2100mm*1530mm*1955mm (L*W*H)
Weight 1850Kg

Ambient temperature

-20℃ to 50℃

Humidity

Up to 100%

Altitude

Up to 2500m

Atmospheric pressure

86 to 106kPa