Product Overview
1) Product overview
Product Features
- High-capacity resistive–inductive load bank from Rata, configured as a 5-unit system rated 5000 kVA / 4000 kW / 3000 kvar (power factor 0.8).
Product Value
- Dual-voltage compatibility: 400 V / 690 V, 3-phase 4-wire. Physical dimensions ~6000 × 2438 × 2900 mm, weight ~18,000 kg, IP54 protection.
Product Advantages
- Specifically designed for ship generator load testing but suitable wherever large generator and system testing is required.
Application Scenarios
2) Product features
- Combined resistive and inductive elements (Ni–Cr alloy resistors and 3‑phase inductors) to simulate real power and reactive loads.
- Cooling by horizontal air discharge with axial fans; robust enclosure rated IP54.
- Flexible control: local panel switching plus remote PC control using Rata-supplied operation software.
- Modular design with easy-to-install / disassemble resistor modules and tin‑plated copper bussing for connections.
- Built and inspected under strict quality controls prior to delivery.
3) Product value
- Enables accurate, full-capacity testing and commissioning of large generators and power systems, reducing commissioning risk.
- Simulates realistic load conditions (including reactive components) to verify generator performance, protection settings and system stability.
- Improves maintenance efficiency and reduces unplanned downtime by validating generator behavior under load before service or deployment.
- Software-enabled remote control simplifies test setup, data capture and repeatable procedures.
4) Product advantages
- Very high rated capacity suitable for large marine and industrial generators.
- Realistic mixed load simulation (resistive + inductive) for comprehensive testing.
- Rugged, weather-tolerant enclosure (IP54) and heavy-duty cooling for reliable operation in demanding environments.
- Modular, serviceable construction for faster installation, maintenance and transport.
- Backed by Rata’s quality management and export experience—professional support and pre-delivery inspection.
5) Application scenarios
- Shipboard and marine generator commissioning and periodic load testing.
- Power plant and industrial generator acceptance tests and maintenance.
- Factory Acceptance Testing (FAT) for generator manufacturers and EPC contractors.
- Emergency/standby generator verification for data centers, hospitals, large facilities.
- Grid-synchronization and protection setting tests where realistic reactive and active loads must be applied.