Product Overview
- RTLBO6-RM is a 6 kW rack-mounted resistive load bank designed primarily for data center use. It fits a standard 19‑inch rack (483 mm × 550 mm, 8U), weighs ~35 kg, and operates on single‑phase 230 Vac at 50–60 Hz. The unit uses finned resistors and forced‑air cooling (4 fans) and is built for long life and reliable operation.
Product Features
- Six 1 kW stepped load elements (standard; customizable) with ±5% element tolerance for accurate power simulation.
- Forced horizontal airflow design (4 × 410 CFM, total ~1640 CFM) compatible with typical rack ventilation.
- Protection and safety: thermal emergency cut‑out, over‑temperature alarm, Schneider circuit breaker, control chamber IP23, insulation test voltage 500 Vac.
- Operational range: 0–75°C, altitude
- Rack‑friendly controls (manual control), 3 C20 load connectors for flexible connections and parallel operation, 3 carrying handles, customizable enclosure color and load step configuration.
Product Value
- Enables realistic, repeatable simulation of server and rack power draws for commissioning, capacity planning and failure testing.
- Validates cooling and airflow design by reproducing server heat dissipation (useful for CRAC/air‑handling performance checks).
- Supports continuous 24/7 testing and long‑term reliability checks thanks to robust resistors and forced‑air cooling.
- Scales easily (parallel units via C20 connectors) to meet larger cluster test requirements.
- Helps meet safety and electrical test standards with appropriate insulation and protection features.
Product Advantages
- Rack‑optimized form factor and horizontal airflow avoid disruption to data center airflow balance.
- Accurate stepped loading with customization options for fine‑tuned testing.
- Strong safety and protection package (thermal shutdown, IP23, 500 Vac insulation test voltage).
- Comprehensive after‑sales support: 3‑year warranty, 24/7 technical support, online meetings, factory reports and documentation.
- Portable and easy to integrate (standard rack size, lightweight for 8U device, optional cables, manual controls with reputable circuit breaker brand).
Application Scenarios
- Data center commissioning and capacity verification (rack‑level and room‑level load tests).
- Cooling/airflow validation and CRAC/CRAH performance verification.
- UPS, generator and power distribution testing under realistic resistive loads.
- Maintenance, resilience drills and continuous burn‑in or endurance testing of power systems.
- Scalable simulation for expansion/renovation projects or large cluster load testing by paralleling multiple units.