Rata Rata Load Bank From China-3

Warranty time:
3 years
Brand:
RATA
Factory Price:
Negotiate
Min.Order Quantity:
1 pcs
Certification:
CE 60204 Standard
Inquiry

Product Overview

- The Rata Rata Load Bank is a 12 kW rack-mounted resistive load unit designed primarily for data centers and server racks. It’s built to simulate the electrical and thermal impact of servers inside a cabinet, providing a compact, space-saving solution for on-site testing and commissioning.

Rata Rata Load Bank From China-3 10
Rata Rata Load Bank From China-3 11

Product Features

- Rack-mounted 12 kW capacity

- MCB (miniature circuit breaker) control for circuit protection

- Adjustable fan speed and horizontal air discharge to match rack airflow patterns

- Master power switch, high-temperature indicator and fan operation indicators for safety and status monitoring

- Robust construction using quality materials and professional assembly

Product Value

- Enables realistic testing of UPS, diesel generators and electrical distribution under full-load conditions

- Validates cooling infrastructure (including free cooling) by reproducing server heat loads, reducing risk of overheating in real operation

- Speeds commissioning and acceptance testing, helping avoid costly downtime and ensuring systems are sized and configured correctly

- Compact rack form factor minimizes footprint and integrates easily into existing cabinet layouts

Rata Rata Load Bank From China-3 12
Rata Rata Load Bank From China-3 13

Product Advantages

- Purpose-built for rack use; aligns with server airflow (horizontal discharge) for accurate thermal simulation

- Safety-oriented controls (MCB, indicators, master switch) and adjustable fans for precise thermal management

- Durable design and materials for consistent performance during repeated tests

- Backed by Deyang Rata Technology’s technical investment and professional customer service, including 24-hour emergency callback support

Application Scenarios

- Integrated Systems Testing (IST) and commissioning of new data centers and data rooms

- Load testing and verification of UPS systems, diesel generators and electrical distribution

- HVAC performance testing and tuning (including free-cooling validation)

- Routine maintenance, acceptance testing and performance validation of individual rack cabinets or groups of racks

- Laboratory or manufacturing test setups where controlled, repeatable electrical and thermal loads are needed

Rata Rata Load Bank From China-3 14


Data Sheet


Product name

12kW rack mounted load bank

Rated voltage

AC230V,1 phase 2 wire

Load steps

1000W×12

Load accuracy (per gear)

±2%

Connection mode

Six input,independent control power input

Insulation class

F

IP ratingIP23

Working mode

Continuous work

Cooling mode

Forced air cooling

Control mode

MCB control

Protection function

High temperature

Color

Customized

Ambient temperature

-20℃ to 50℃

Humidity

Up to 100%

Altitude

Up to 2500m

Atmospheric pressure

86 to 106kPa