loading
Rata Rata Load Bank Rata Load Bank Company-2 1
Rata Rata Load Bank Rata Load Bank Company-2 2
Rata Rata Load Bank Rata Load Bank Company-2 3
Rata Rata Load Bank Rata Load Bank Company-2 4
Rata Rata Load Bank Rata Load Bank Company-2 5
Rata Rata Load Bank Rata Load Bank Company-2 6
Rata Rata Load Bank Rata Load Bank Company-2 1
Rata Rata Load Bank Rata Load Bank Company-2 2
Rata Rata Load Bank Rata Load Bank Company-2 3
Rata Rata Load Bank Rata Load Bank Company-2 4
Rata Rata Load Bank Rata Load Bank Company-2 5
Rata Rata Load Bank Rata Load Bank Company-2 6

Rata Rata Load Bank Rata Load Bank Company-2

ISO Certification:
ISO9001/ISO14001
Brand:
RATA
Payment Terms:
L/C,Cash,Western Union,T/T, Paypal
Min.Order Quantity:
1 pcs
ODM & OEM:
Available
Inquiry

Product Overview

- Model: Rata-R100kW/L75kvar/415V/PF0.8 — a 125 kVA resistive/reactive load bank from Rata (100 kW active, 75 kVAR reactive).

- Rated for 415 V, 50/60 Hz with a nominal power factor ~0.8 and minimum step resolution of 1 kW / 1 kVAR.

- Designed for continuous operation with forced-air cooling; size ~1860 × 1100 × 1540 mm and weight ~500 kg.

- Customizable capacities and configurations available to meet different market and project needs.

Rata Rata Load Bank Rata Load Bank Company-2 7
Rata Rata Load Bank Rata Load Bank Company-2 8

Product Features

- Combined resistive and inductive loading (100 kW resistive, 75 kVAR inductive) with fine loading steps (1 kW / 1 kVAR minimum).

- Dual control: local touch-screen interface and remote PC control via RS485 (approx. 30 m).

- Monitoring and display of voltage, current, active/reactive power, frequency and power factor; sampling accuracy Level 0.5, load accuracy ±2%.

- Robust protections: over-current, over-voltage, short circuit, high temperature, low air volume and emergency shutdown.

- Copper-bar wiring (L1, L2, L3, N), three-phase four-wire control power (380 VAC), forced horizontal air inlet/outlet cooling.

Product Value

- Provides precise, repeatable, and safe electrical loading for commissioning, acceptance testing and routine maintenance of generators, UPS, switchgear and power systems.

- Supports both active and reactive loading so users can validate power-factor behavior and thermal performance under realistic conditions.

- Customizability and accurate step control reduce testing time and increase confidence in system performance and reliability.

- Backed by factory QC, a professional test lab and trained after-sales service for reliable long-term support.

Rata Rata Load Bank Rata Load Bank Company-2 9
Rata Rata Load Bank Rata Load Bank Company-2 10

Product Advantages

- High resolution loading (1 kW / 1 kVAR) and combined resistive/reactive capability for versatile, realistic testing.

- Flexible control options (local touch screen plus remote PC/RS485) for on-site and off-site operation.

- Comprehensive protection and forced-air cooling enable continuous, safe operation across a wide ambient range (-10 °C to +50 °C).

- Scalable and customizable platform with many power/voltage options and a short typical delivery lead time (about 30 days) and 1-year warranty.

- Established manufacturer support: experienced QC, professional lab testing and trained after-sales personnel.

Application Scenarios

- Commissioning and acceptance testing of diesel/gas generator sets and prime movers.

- Routine load testing and maintenance of UPS systems, data centers and critical power infrastructure.

- Factory and site testing of switchgear, transformers and protection systems.

- Power system performance and power-factor correction verification in industrial plants, utilities and commercial facilities.

- Research, training and test labs that require controlled, repeatable resistive and reactive load profiles.

Rata Rata Load Bank Rata Load Bank Company-2 11
Contact us
we welcome custom designs and ideas and is able to cater to the specific requirements. for more information, please visit the website or contact us directly with questions or inquiries.
no data
Customer service
detect