loading
Rata Wholesale Generator Load Bank for Sale Company 1
Rata Wholesale Generator Load Bank for Sale Company 2
Rata Wholesale Generator Load Bank for Sale Company 3
Rata Wholesale Generator Load Bank for Sale Company 4
Rata Wholesale Generator Load Bank for Sale Company 5
Rata Wholesale Generator Load Bank for Sale Company 6
Rata Wholesale Generator Load Bank for Sale Company 1
Rata Wholesale Generator Load Bank for Sale Company 2
Rata Wholesale Generator Load Bank for Sale Company 3
Rata Wholesale Generator Load Bank for Sale Company 4
Rata Wholesale Generator Load Bank for Sale Company 5
Rata Wholesale Generator Load Bank for Sale Company 6

Rata Wholesale Generator Load Bank for Sale Company

Inquiry

Product Overview

Here is the summary of the product "Rata Wholesale Generator Load Bank for Sale Company" based on the detailed introduction:

Rata Wholesale Generator Load Bank for Sale Company 7
Rata Wholesale Generator Load Bank for Sale Company 8

Product Features

**Product Overview**

Product Value

The Rata R100kW/400V/50Hz load bank is a customized low-voltage pure resistive load bank designed primarily for generator testing and performance verification. It features a rated current of 145A, power factor of 1.0, and multiple step settings ranging from 1kW to 90kW. The control panel includes indicators and alarms such as phase sequence, electrical instruments, low air volume alarm, and fan start switch. It supports both local manual control and remote PC control, ensuring flexible operation. The product is backed by a 2-year warranty and complies with relevant national, military, and industry standards.

Rata Wholesale Generator Load Bank for Sale Company 9
Rata Wholesale Generator Load Bank for Sale Company 10

Product Advantages

**Product Features**

Application Scenarios

- Pure resistive load with a power factor of 1.0 for accurate generator testing

- Multiple step load settings (1kW, 2*2kW, 5kW, 9*10kW) for precise load control

- Comprehensive control panel with phase sequence indicator, electrical instrument, alarm system, and fan control

- Dual control modes: local manual and remote PC control

- Comes with accessory documents including operation manuals, acceptance certificates, inspection reports, electrical schematics, and PC software

**Product Value**

The load bank provides an effective and reliable solution for testing and maintaining generators, helping customers ensure their generators perform optimally under various load conditions. Its customization ability allows clients to have tailored solutions that best fit their operational requirements. By adhering to strict quality management and industry standards, it ensures safety, durability, and long-term dependable performance, reducing downtime and maintenance costs.

**Product Advantages**

- Consistent quality and stable performance due to technologically advanced manufacturing processes and strong quality control systems

- Durable construction with long service life suitable for prolonged industrial use

- Flexible design that can be adjusted to customer-specific needs

- Supported by the strong management and technical experience of Deyang Rata Technology Co., LTD, a recognized leader in the sector

- Fashionable and customizable design patterns available to meet client preferences

**Application Scenarios**

The Rata load bank is widely used in industrial settings to test and verify the performance of diesel and other types of generators, including marine and military applications. It is suitable for facilities requiring reliable generator load testing such as power plants, manufacturing plants, shipyards, and military bases. Its adaptability allows modifications to tailor load test solutions for various customer-specific operational environments.

Rata Wholesale Generator Load Bank for Sale Company 11

Data sheet

Note: all parameters are for reference only and can be customized

Product name

100kW load bank

Specifications

R100kW/400V/50Hz

Formation

One load bank(Including dry resistance load, electrical control components, measurement and control system)

Load steps

1kW, 2*2kW, 5kW, 2*10kW, 20kW, 50kW

Load connection

Copper bar

Resistor

Each resistance element: insulation impedance DC1000V/100MΩ above

Withstand voltage AC 2000V for 5min

Resistance error of each resistance tube: ±3%

Load control

Local manual control and remote PC control

Loading accuracy

≤ 3%

Three phase balance

Unbalance degree ≤ 3%

Minimum step

1kW

Working mode

Continuous work

Load protection

Short circuit, overcurrent, high temperature, fan fault protection

External power

380V/50Hz

Cooling mode

Forced air cooling, horizontal air outlet

Insulation class

F

Measurement accuracy

The display accuracy is 0.5,the sampling accuracy is 0.2

Electrical parameter display

Three phase voltage, three-phase current, frequency, power, etc

Load expansion

Parallel expansion of multiple loads

Standard

Meet international standard, ship standard, military standard and telecommunication standard

Transport

The load bank has a load-bearing lifting hole, which meets the requirements of long-distance transportation

Color

Customized

Dimensions 900mm*850mm*700mm (L*W*H)
Weight 120Kg

Ambient temperature

-20℃ to 50℃

Humidity

Up to 100%

Altitude

Up to 2500m

Atmospheric pressure

86 to 106kPa

 

More specifications

Note: all parameters are for reference only and can be customized

Power(kW)

Voltage(kV)

Frequency(Hz)

Size(mm,L*W*H)

Weight(Kg)

100

0.4

50/60

1100*900*1000

320

200

0.4

50/60

1350*1100*1100

450

300

0.4

50/60

1500*1200*1200

650

400

0.4

50/60

1700*1500*1500

830

500

0.4

50/60

1700*1500*1500

950

600

0.4

50/60

1800*1600*1600

1150

800

0.4

50/60

1900*1800*1700

1900

1000

0.4

50/60

2300*1700*2100

2100

1200

0.4

50/60

2500*1800*2200

2300

1500

0.4

50/60

2500*1860*2300

2600

1800

0.4

50/60

3000*2000*2300

4000

2000

0.4

50/60

3000*2000*2300

5000

2500

0.4

50/60

4000*2438*2500

6000

3000

0.4

50/60

6000*2438*2500

7000

 

Contact us
we welcome custom designs and ideas and is able to cater to the specific requirements. for more information, please visit the website or contact us directly with questions or inquiries.
no data
Customer service
detect