Product Overview

1) Product overview

Wholesale Resistive Load Bank for Sale​ by Rata-2 4
Wholesale Resistive Load Bank for Sale​ by Rata-2 5

Product Features

- 600 kW AC resistive load bank (specification example: R600kW/400VAC/50Hz/PF1.0) designed for performance testing and aging of high‑power UPS, inverters, switching power supplies and diesel generator sets.

Product Value

- Modular, single‑container formation including dry resistance elements, electrical control components and measurement/control system.

Wholesale Resistive Load Bank for Sale​ by Rata-2 6
Wholesale Resistive Load Bank for Sale​ by Rata-2 7

Product Advantages

- Continuous operation capability with forced‑air cooling and options for side or top air outlet.

Application Scenarios

2) Product features

- Dry resistance elements with high insulation and withstand voltage (insulation DC1000V/100MΩ+, AC 2000V/5min).

- High power density, no “red‑heat” phenomenon, automatic overheat protection and protection against fan failure.

- Load control: local manual, local automatic or remote automatic; minimum step 1 kW; loading accuracy ≤3%; three‑phase unbalance ≤3%.

- Measurement/display of three‑phase voltage, currents, frequency, power; display accuracy 0.5, sampling accuracy 0.2.

- Expandable by parallel connection of multiple load containers; transport features (lifting holes, optional rollers); customizable color and parameters.

3) Product value

- Provides scientific, repeatable and reliable means to validate and commission high‑power AC power equipment, reducing field failures and downtime.

- Enables full performance, endurance and safety verification for manufacturers, service providers and end users.

- Customizable and modular design shortens installation, maintenance and upgrade cycles and improves lifecycle management of power systems.

4) Product advantages

- Independently developed power consumption components and modular architecture for easier maintenance and high reliability.

- Robust safety suite: short‑circuit, overcurrent, overtemperature and fan‑fault protections plus automatic overheating protection to prevent element burning.

- High measurement accuracy and fine load step resolution offering precise, reproducible test conditions.

- Compliance capability with international, marine, military and telecommunication standards; on‑site and factory acceptance testing and supplier training support.

5) Application scenarios

- Commissioning, routine testing and aging of UPS systems, inverters, switching power supplies and diesel generator sets.

- Manufacturing test benches for power equipment and quality control labs.

- Data centers, telecommunication sites, power stations and military or shipboard power testing where standards compliance and reliable load simulation are required.

- Field service, maintenance contractors and rental/test houses performing site acceptance testing and on‑site diagnostic verification.

Wholesale Resistive Load Bank for Sale​ by Rata-2 8
Data Sheet

 

Note: all parameters are for reference only and can be customized

Product name

600kW load bank

Specifications

R600kW/400VAC/50Hz/PF1.0

Formation

One load bank(Including dry resistance load, electrical control components, measurement and control system)

Load step

According to customer needs

Load connection

Copper bar

Resistor

Each resistance element: insulation impedance DC1000V/100MΩ above

Withstand voltage ac 2000V for 5min

Resistance error of each resistance tube:±3%

Load control

Local manual control, local automatic control or remote automatic control can be selected

Loading accuracy

Less than or equal to 3%

Three phase balance

Unbalance degree less than or equal to 3%

Minimum step

1kW

Working mode

Continuous work

Load protection

Short circuit, overcurrent, high temperature, fan fault protection

External power

TN-C,380V/50Hz

Cooling mode

Forced air cooling, side air outlet or top air outlet

Insulation class

F

Measurement accuracy

The display accuracy is 0.5,the sampling accuracy is 0.2

Electrical parameter display

Three phase voltage, three-phase current, frequency, power, etc

Load expansion

Parallel expansion of multiple load containers

Standard

Meet international standard, ship standard, military standard and telecommunication standard

Transport

The load bank is equipped with load-bearing lifting holes, and the bottom can be equipped with rollers to meet the requirements of long-distance transportation

Color

Customized

Ambient temperature

-20℃ to 50℃

Humidity

Up to 100%

Altitude

Up to 2500m

Atmospheric pressure

86 to 106kPa

Load Bank Design

Load bank outdoor design

Contact us
we welcome custom designs and ideas and is able to cater to the specific requirements. for more information, please visit the website or contact us directly with questions or inquiries.