600 kW load bank is mainly used for performance testing and aging of online high-power UPS, inverter, switching power supply and diesel generator set of power, telecommunications and other departments and manufacturers.

    oops...!

    no product data.

    Go to homepage

    The product is so popular in the industry that many customers make full use of it.

     

    PRODUCT OVERVIEW


    600 kW load bank is mainly used for performance testing and aging of online high-power UPS, inverter, switching power supply and diesel generator set of power, telecommunications and other departments and manufacturers. AC 600 kW load bank has unified segmented power input, energy consumption working mode and forced air cooling heat dissipation, which greatly ensures the reliability of constant power discharge; The internal heat dissipation element adopts dry resistance and forced air cooling heat dissipation. AC 600 kW load bank is produced with independent intellectual property rights of new power consumption components, with high power density, no red heat phenomenon, automatic overheating protection function, no overheating and burning loss when the fan does not run, and long safety life; The AC dummy load machine adopts modular design, which is simple to operate and convenient to maintain; The 600kW load bank provides scientific detection means for high-power AC power supply equipment.

     

    PRODUCT PICTURE


     

    600kW load bank

     

     

    APPLICATION SCENARIO


    product-750-569

    PARTIAL PARAMETERS


     

    Note: all parameters are for reference only and can be customized

    Product name

    600kW load bank

    Specifications

    R600kW/400VAC/50Hz/PF1.0

    Formation

    One load bank(Including dry resistance load, electrical control components, measurement and control system)

    Load step

    According to customer needs

    Load connection

    Copper bar

    Resistor

    Each resistance element: insulation impedance DC1000V/100MΩ above

    Withstand voltage ac 2000V for 5min

    Resistance error of each resistance tube:±3%

    Load control

    Local manual control, local automatic control or remote automatic control can be selected

    Loading accuracy

    Less than or equal to 3%

    Three phase balance

    Unbalance degree less than or equal to 3%

    Minimum step

    1kW

    Working mode

    Continuous work

    Load protection

    Short circuit, overcurrent, high temperature, fan fault protection

    External power

    TN-C,380V/50Hz

    Cooling mode

    Forced air cooling, side air outlet or top air outlet

    Insulation class

    F

    Measurement accuracy

    The display accuracy is 0.5,the sampling accuracy is 0.2

    Electrical parameter display

    Three phase voltage, three-phase current, frequency, power, etc

    Load expansion

    Parallel expansion of multiple load containers

    Standard

    Meet international standard, ship standard, military standard and telecommunication standard

    Transport

    The load bank is equipped with load-bearing lifting holes, and the bottom can be equipped with rollers to meet the requirements of long-distance transportation

    Color

    Customized

    Ambient temperature

    -20℃ to 50℃

    Humidity

    Up to 100%

    Altitude

    Up to 2500m

    Atmospheric pressure

    86 to 106kPa

     

    FACTORY ACCEPTANCE AND SITE ACCEPTANCE


    Factory Acceptance

    Both parties may check and accept the system through actual operation.After the production of the system, the user shall be notified of the performance experiment before leaving the factory 3 days in advance, and the factory can pass the acceptance.Observe the following items during the acceptance inspection:

    1) The factory acceptance test shall be carried out in accordance with the technical agreement and the acceptance outline agreed by both parties.

    2) The Seller shall appoint technical backbone to provide technical services and training.

    3) When it first uses the system, the technicians involved in the acceptance will be fully guided and teach the methods.

    4) Guide users to install and debug according to technical data and drawings.

    5) The Seller is responsible for solving the problems arising in the manufacturing process.

    6) Factory acceptance test is only functional test, load test as the final acceptance item, in the user formal load test.

     

    600kW load bank factory acceptance test

     

    Site Acceptance

    After the system, the Seller sends personnel to the site for complete function and load test acceptance, including the following:

    1) The Seller is responsible for the transportation of the system and ensures that all accessories of the system reach the place designated by the user before the agreed date.

    2) The Seller shall be responsible for the site installation and commissioning of the system. The site acceptance test shall be conducted in accordance with the technical agreement and the acceptance outline agreed by both parties (the test unit and fuel are provided by the user) and guaranteed to be delivered to the user before the agreed date.

    3) The Seller provides relevant training for the user's technical personnel to meet the daily work and maintenance needs of the system.

    4) During the training, the Seller assigns experienced technical personnel as guidance, and develops a detailed training outline for theoretical and practical content (to provide electronic training courses and materials).

    5) Ensure that the trained personnel understand the working principle, operation methods, precautions, various abnormal response methods and daily maintenance methods of the system.

    The product is completely examined by the quality testing department.

    Data Sheet

     

    Note: all parameters are for reference only and can be customized

    Product name

    600kW load bank

    Specifications

    R600kW/400VAC/50Hz/PF1.0

    Formation

    One load bank(Including dry resistance load, electrical control components, measurement and control system)

    Load step

    According to customer needs

    Load connection

    Copper bar

    Resistor

    Each resistance element: insulation impedance DC1000V/100MΩ above

    Withstand voltage ac 2000V for 5min

    Resistance error of each resistance tube:±3%

    Load control

    Local manual control, local automatic control or remote automatic control can be selected

    Loading accuracy

    Less than or equal to 3%

    Three phase balance

    Unbalance degree less than or equal to 3%

    Minimum step

    1kW

    Working mode

    Continuous work

    Load protection

    Short circuit, overcurrent, high temperature, fan fault protection

    External power

    TN-C,380V/50Hz

    Cooling mode

    Forced air cooling, side air outlet or top air outlet

    Insulation class

    F

    Measurement accuracy

    The display accuracy is 0.5,the sampling accuracy is 0.2

    Electrical parameter display

    Three phase voltage, three-phase current, frequency, power, etc

    Load expansion

    Parallel expansion of multiple load containers

    Standard

    Meet international standard, ship standard, military standard and telecommunication standard

    Transport

    The load bank is equipped with load-bearing lifting holes, and the bottom can be equipped with rollers to meet the requirements of long-distance transportation

    Color

    Customized

    Ambient temperature

    -20℃ to 50℃

    Humidity

    Up to 100%

    Altitude

    Up to 2500m

    Atmospheric pressure

    86 to 106kPa