Data Center Load Bank Series Product Solutions

Data Center Product Distribution Diagram

Data Center Product Distribution Diagram

Rack mounted load bank 

Optional:

Customizable voltage range: 110V/220V/230V/240V.

Display instrument can be added.

The fan speed regulation function can be added .

Double power input interface for automatic switching can be added.

Inductive or resistive inductive rack mounted load bank can be customized.

By default, only 6kW to 12KW are equipped with high temperature protection function. All models support adding all protection functions. 

Partial parameters:

Load accuracy:

±2%

Control power:

AC220V/50Hz

Control mode:

Load switching of manual miniature circuit breaker

Cooling mode:

Forced air cooling,forward air,rear air

Insulation class:

F

Color:

Customized

Ambient temperature

-20to 50

Product series table:

Model

Power

Voltage

Frequency

RT-RM-3

3kW

AC230V

50Hz/60Hz

RT-RM-3.5

3.5kW

AC230V

50Hz/60Hz

RT-RM-4

4kW

AC230V

50Hz/60Hz

RT-RM-4.5

4.5kW

AC230V

50Hz/60Hz

RT-RM-5

5kW

AC230V

50Hz/60Hz

RT-RM-5.5

5.5kW

AC230V

50Hz/60Hz

RT-RM-6

6kW

AC230V

50Hz/60Hz

RT-RM-7

7kW

AC230V

50Hz/60Hz

RT-RM-8

8kW

AC230V

50Hz/60Hz

RT-RM-9

9kW

AC230V

50Hz/60Hz

RT-RM-10

10kW

AC230V

50Hz/60Hz

RT-RM-12

12kW

AC230V

50Hz/60Hz

Low voltage resistive load bank 

Optional:

Voltage 380V/400V/415V/440V

The protection level can be customized IP54

Customizable remote automatic control mode

Can add casters

Optional local touch screen operation

Customized customer logo and color

The wiring mode can be copper bar or quick plug

Partial parameters:

Control method

Local manual

Cooling method

Forced air cooling

Line entry

Down line

Protection function

High temperature, air volume, overcurrent, phase sequence, emergency stop

Use environment

Indoor

Protection class

IP23

Display accuracy

0.5

Sampling accuracy

0.2

Application scenarios

UPS lumped load test

Ambient temperature

-20to 50

Humidity

Up to 100%

Product series table

Model

Power

Voltage

Frequency

PF

RT-L-R-200

200kW

AC400V

50Hz/60Hz

1

RT-L-R-300

300kW

AC400V

50Hz/60Hz

1

RT-L-R-500

500kW

AC400V

50Hz/60Hz

1

RT-L-R-800

800kW

AC400V

50Hz/60Hz

1

RT-L-R-1000

1000kW

AC400V

50Hz/60Hz

1

RT-L-R-1200

1200kW

AC400V

50Hz/60Hz

1


Low voltage resistive capacitive load bank

Optional:

Voltage 380V/400V/415V/440V

The protection level can be customized IP54

Customizable remote automatic control mode

Can add casters

Optional local touch screen operation

Customized customer logo and color

The wiring mode can be copper bar or quick plug

Partial parameters:

Control method

Local manual

Cooling method

Forced air cooling

Line entry

Down line

Protection function

High temperature, air volume, overcurrent, phase sequence, emergency stop

Use environment

Indoor

Protection class

IP23

Display accuracy

0.5

Sampling accuracy

0.2

Ambient temperature

-20to 50

Humidity

Up to 100%

Product series table

Model

Power

Voltage

Frequency

PF

RT-L-RC-200

200kW

AC400V

50Hz/60Hz

0.9

RT-L-RC-300

300kW

AC400V

50Hz/60Hz

0.9

RT-L-RC-500

500kW

AC400V

50Hz/60Hz

0.9

RT-L-RC-800

800kW

AC400V

50Hz/60Hz

0.9

RT-L-RC-1000

1000kW

AC400V

50Hz/60Hz

0.9

RT-L-RC-1200

1200kW

AC400V

50Hz/60Hz

0.9

 

Medium voltage resistive load bank

Optional:

Voltage can be customized low voltage 380V/4 00V/415V/440V/690V , and 400V/690V can be switched

Customizable top air outlet

Customizable local touchscreen control

Customized customer logo and color

The wire entry method can be selected as bottom entry or side entry.

Optional electric blinds.

Configurable remote console.

Partial parameters:

Control method

Local manual

Cooling method

Forced air cooling

Line entry

Down line

Protection function

High temperature, air volume, overcurrent, phase sequence, emergency stop

Protection class

IP23

Display accuracy

0.5

Sampling accuracy

0.2

Ambient temperature

-20to 50

Product series table

Model

Power

Voltage

Frequency

PF

RT-MR-1500

1500kW

10.5kV

50Hz/60Hz

1

RT-MR-1600

1600kW

10.5kV

50Hz/60Hz

1

RT-MR-1800

1800kW

10.5kV

50Hz/60Hz

1

RT-MR-2000

2000kW

10.5kV

50Hz/60Hz

1

RT-MR-2200

2200kW

10.5kV

50Hz/60Hz

1

 

Medium voltage resistive capacitive load bank

Optional:

Voltage can be customized low voltage 380V/4 00V/415V/440V/690V, and 400V/690V can be switched

Customizable top air outlet

Customizable local touch screen control

Customized logo and color can be customized

The incoming line can be selected as bottom incoming line or side incoming line.

Optional electric shutters .

Configurable remote console .

Partial parameters:

Control method

Local manual

Cooling method

Forced air cooling

Working mode

Continuous

Line entry

Down line

Protection function

High temperature, air volume, overcurrent, phase sequence, emergency stop

Use environment

Indoor

Protection class

IP54

Display accuracy

0.5

Sampling accuracy

0.2

Ambient temperature

-20to 50

Humidity

Up to 100%

Warranty period

3 years

Delivery time

30 days

Product series table

Model

Power

Voltage

Frequency

PF

RT-MRC-1500

1500kW

10.5kV

50Hz/60Hz

0.9

RT-MRC-1600

1600kW

10.5kV

50Hz/60Hz

0.9

RT-MRC-1800

1800kW

10.5kV

50Hz/60Hz

0.9

RT-MRC-2000

2000kW

10.5kV

50Hz/60Hz

0.9

RT-MRC-2200

2200kW

10.5kV

50Hz/60Hz

0.9


Battery discharge tester

Optional:

Single voltage detection module

Fluke clamp instrument

Extended load unit

Partial parameters:

Current test accuracy

1%

Whole group voltage resolution

0.01V

Voltage test accuracy

0.5%

Modbus

RS232,USB

Control mode

7 inch LCD touch screen

Working voltage

AC 220V±15%

Insulated interface

Equipped with grounding point

Product series table

Rated voltage

Input Voltage

Discharge

current

Applicable battery pack voltage

48V

19-60V

0-30A,50A,100A,150A,200A,300A,

24V,36V,48V

96V

57-132V

0-30A,50A,100A,

150A,200A,300A

72V,96V,110V

110V

88-132V

0-30A,50A,100A,

150A,200A,300A

96V,110V

220V

176-264V

0-30A,50A,100A,

150A,200A,300A

220V,240V

380V

304-456V

0-30A,50A,100A,

150A,200A

380V

480V

384-600V

0-30A,50A,

100A,150A

480V


Grounding resistance cabinet

NETR-100A-58Ω-10S

Neutral grounding through resistance is to connect a resistor in series between the neutral point of the power grid and the ground. Proper selection of the resistance value of the connected resistor can not only release the energy of the second half wave of the single-phase grounding arc, thus reducing the possibility of arc re ignition and suppressing the radiation value of the grid overvoltage, but also improve the sensitivity of the relay protection device to act on tripping, thus effectively protecting the normal operation of the system.

The neutral grounding resistance cabinet of transformer is a complete set of grounding equipment including grounding transformer, which can be installed in the auxiliary power system of power plant, power supply system of substation and power distribution system of industrial and mining enterprises to realize the system operation mode of neutral grounding through resistance for these power grids.

ABOUT RATA:

Rata is an original manufacturer of load bank in China. Since its establishment, Rata has obtained 23 utility model patents and 8 computer software copyright registration certificates. In addition, Rata is a national high-tech enterprise and an enterprise certified by the ISO9001: 2015 quality management system.

Since its establishment, Rata has continuously delivered nearly 10000 sets of load bank products to data centers and third-party testing institutions around the world. The quality of its products has been strongly recognized by buyers. 

Pre-sales:

Implementation plan: Before you purchase our products, our customer service will communicate with you about your technical requirements in detail, and provide you with professional production technical proposals and reasonable quotations. After you approve our plan and pay an advance payment, you can start the production task.

Signing the contract: In order to provide you with reliable product quality assurance and delivery time assurance, we suggest to conduct transactions through Alibaba Sinosure orders.

Payment method: We provide you with reliable payment methods, including 50% advance payment, 40% delivery of the preceding paragraph and 10% acceptance payment. We suggest TT payment, but you can also negotiate other payment methods with us.

Production and delivery:

After the production task is officially started, our customers will confirm the necessary product requirements with you again to ensure that the finished products are as you want.

Our product components are selected from international famous brands such as ABB, Schneider, etc.

Our sales staff will provide you with production progress throughout the process, including but not limited to text, pictures and videos.

Generally, the average production cycle time of our products is 30 days, which depends on the complexity of the products.

At the time of delivery, we will try our best to provide you with all the accessories (including quality inspection reports) and vulnerable parts you want. 

After-sales:

The warranty period is 3 years from the date of product acceptance. In addition, we provide lifelong free technical consultation.

During the warranty period, the Seller shall provide 7 * 24h remote technical support for any quality problem of the system.

In case of a difficult problem, we will come to your place to deal with it, and will not leave until the problem is solved.

If necessary, the seller will upgrade the system for users at the most favorable price.

verlieben
Das Problem der Dummy-Load-Bank in verschiedenen Umgebungen und ihre Lösung